Lincoln Electric POWER Wave AC/DC 1000 Operator's Manual page 53

Hide thumbs Also See for POWER Wave AC/DC 1000:
Table of Contents

Advertisement

E-2
PROBLEMS
(SYMPTOMS)
Major physical or electrical damage
is evident when the sheet metal
covers are removed.
Input fuses keep blowing.
Machine will not power up (no
lights)
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
OUTPUT PROBLEMS
1.
Contact your local authorized
Lincoln Electric Field Service
facility for technical assistance.
1.
Improperly sized input fuses.
2.
Improper Weld Procedure
requiring output levels in
excess of machine rating.
3.
Major physical or electrical
damage is evident when the
sheet metal covers are
removed.
1.
No Input Power.
2.
Circuit breaker CB4 (in recon-
nect area) may have tripped.
Power Down and Reset CB4.
3.
Input voltage selection made
improperly.
POWER WAVE® AC/DC 1000
CAUSE
CAUTION
RECOMMENDED
COURSE OF ACTION
1.
Contact your local authorized
Lincoln Electric Field Service
facility for technical assistance.
1.
Make sure fuses are properly
sized. See Installation section
of this manual for recom-
mended sizes.
2.
Reduce output current, duty
cycle, or both.
3.
Contact an authorized Lincoln
Electric Service facility.
1.
Make sure input supply dis-
connect has been turned ON.
Check input fuses. Make cer-
tain that the Power Switch
(SW1) on the power source is
in the "ON" position.
2.
Power Down and Reset CB4.
3.
Power down, check input volt-
age reconnect according to
diagram on reconnect cover.
(Qualified person should
perform this operation)