Lincoln Electric POWER Wave AC/DC 1000 Operator's Manual page 48

Hide thumbs Also See for POWER Wave AC/DC 1000:
Table of Contents

Advertisement

B-10
WELD PROCESS ADJUSTMENTS
Depending on the weld mode, there are a number of
adjustments that can be made, including but not limit-
ed to Current, Voltage and WFS. These adjustments
apply to either AC or DC processes, and control the
basic parameters of the weld.
AC ADJUSTMENTS
In addition to the basic weld parameters, there are a
number of unique adjustments related to the AC
waveform of the Power Wave AC/DC 1000. These
adjustments enable the operator to balance the rela-
tionship between penetration and deposition to tailor
the output for specific applications.
WAVE BALANCE
• Refers to amount of time the waveform spends in
DC+ portion of the cycle.
• Use Wave Balance to control the penetration and
deposition of a given process.
Wave Balance
Increased Balance
1000
More Penetration
Nominal Balance
Less Deposition
500
0
-500
-1000
OPERATION
DC OFFSET
• Refers to +/- shift of the current waveform with
respect to the zero crossing.
• Use Offset to control the penetration and deposition
of a given process.
1000
500
0
-500
-1000
FREQUENCY
• POWER WAVE AC/DC 1000 can produce Output
Frequencies from 10 - 100Hz
Decreased Balance
• Use Frequency to fine tune stability
Less Penetration
• Higher frequencies in multiple arc setups can help
More Deposition
reduce arc interaction
1000
500
0
-500
-1000
POWER WAVE® AC/DC 1000
DC Offset
Positive Offset
More Penetration
Less Deposition
Nominal Offset
Frequency
Use Frequency to fin e tune stability of
imb alanced waveform s and multipl e arc syst ems
Decrease
B-10
Negative Offset
Less Penetration
More Deposition
Increase

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents