Electrical Connection; Intake Air, Ambient Air; Condensate Drain - Miele PT 8257 WP Operating And Installation Instructions

Table of Contents

Advertisement

Installation

Electrical connection

The electrical connections must be carried out by a
certified electrician in accordance with all the national
regulations.
Observe the enclosed wiring diagram.
Before installation, make sure that the voltage and
frequency listed on the data plate correspond with
the site's electrical supply.
(EL) Electrical connection, (SLA) Peak load cutout
If the appliance is hard wired, a multiple-pole
separator must be installed. Separators with a
contact gap of more than 1/8" (3 mm) are valid as
separators. All components have to bear CSA or UL
approval.
The plug connection or the separator must be
accessible at all times.
You must be able to lock the separator or monitor it at
all times in case the appliance has to be
disconnected from the power supply.
When the dryer has been connected, check the
rotation direction of the compressor.
,
An incorrect phase connection will result in a
loud, chattering noise. Incorrect compressor
rotation direction will damage the system and must
be stopped immediately.
32

Intake air, ambient air

(EA) exhaust air, (IA) intake air, (CD) condensate
drain
The dryer may be operated only if there is a supply of
adequately cool fresh air. If ambient temperature
frequently exceeds 113°F (45°C), the cooling circuit
of the heat pump must be connected to an external
intake and exhaust air line.

Condensate drain

The dryer with heat pump operates according to the
principle of condensation. The appearing
condensation water must be drained separately via a
floor drain.
The C 1 3/16" (30 mm) condensation water drain is
located on the rear of the water pump and can be
routed to the floor drain via a hose or downward
sloping pipe.
,
Once the system has been installed, replace
all the outer housing parts that were removed.