Active Vent; Inner Door Panel - GE GDWT668V Technical Service Manual

Top-control stainless steel tub dishwashers
Hide thumbs Also See for GDWT668V:
Table of Contents

Advertisement

4. Remove the 4 Phillips-head screws from the
back of the vent fan.
5. Remove the 2 Phillips-head screws from the
bottom of the vent fan.

Active Vent

The active vent is attached to the inner door panel
between the vent and door switch. It operates on 12
VDC and has a resistance of 103 The vent motor
turns the active vent switch clockwise to close the
vent and counterclockwise to open the vent.
To remove the active vent:
1. Remove the vent fan. (See
2. Disconnect the active vent wire harness.
Disconnect
, steps 1-3.)
Vent Fan
– 26 –
3. Remove the single Phillips-head screw from the
vent switch housing.

Inner Door Panel

To remove the inner door panel:
1. Remove the control TCO. (See
2. Disconnect 3 wire harnesses from the control
board.
Disconnect
Disconnect
Control TCO.)
Disconnect
(Continued next page)