Vent Fan - GE GDWT668V Technical Service Manual

Top-control stainless steel tub dishwashers
Hide thumbs Also See for GDWT668V:
Table of Contents

Advertisement

The detergent/rinse mod ule au to mat i cal ly
dis pens es both de ter gent and rinse agent at the
ap pro pri ate times. The module is activated twice
during a wash cycle. Detergent is dispensed at the
beginning of the main wash cycle and rinse agent at
the beginning of the fi nal rinse.
Operation of the detergent/rinse module can be
checked by using the service test mode. (See
.)
Mode
The fi rst time the module is activated, the lever
slides up the right-hand path of the connecting rod
(1). This action releases the de ter gent cover.
When the module is deactivated, the lever returns
down the left-hand path and comes to rest under
the notch (2) in the center of the connecting rod.
At the second activation of the module, the lever lifts
the con nect ing rod by the notch. This action lifts the
rinse dispenser plunger (3) and re leas es the rinse
agent. When the module is deactivated, the lever
returns to its original start ing position.
Service
1
2
3
– 25 –

Vent Fan

The vent fan runs at the end of the dry cycle,
whether HEATED DRY has been selected or not. It
will run for 1 to 15 minutes when not in HEATED
DRY and 30 to 50 minutes during some HEATED
DRY cycles. The vent is located on the upper-left
side of the inner door panel and has a resistance of
65 .
To remove the vent fan:
1. Remove the outer door panel. (See
Panel.)
2. Disconnect the vent fan wire harness.
Disconnect
3. Remove the 4 Phillips-head screws from the
vent fan and lift it off the conduit exhaust.
Outer Door
Conduit
(Continued next page)