General Description The Cloud CX163 is a stereo mixer zoner with two stereo zone outputs and a mono, fixed level utility output. It has applications where up to six line level music signals and one microphone are required to feed two separate zones (both stereo) and a utility zone (such as toilet areas etc.).
The Cloud CX163 occupies one unit of standard 19” equipment rack. The microphone input and all zone outputs are balanced. The CX163 is 150mm deep but a depth of 250mm should be allowed to clear connectors and cables. Ventilation holes on the base of the unit should not be obscured.
The input sensitivity can be varied from -18dBu (100mV) to + 6dBu (1.5V). The pre-set gain controls should be set so that all the input signals operate at the same level (0dBu) within the CX163 to give the music level controls an optimum control range.
• Remove the mains cable from the rear of the product before removing the top panel. • Only reassemble the unit using screws identical to the original parts. NOTE: The CX163 does not allow remote source selection, so it is incompatible with the RSL-6 remote wallplates. 5.3 Music Equalisation...
This provides the facility for paging microphones, such as the Cloud CPM-4, to be connected to the CX163. The access contacts work on a short-to-ground system, which is compatible with the majority...
Front panel microphone level controls are provided for each stereo zone. Microphone level to the utility zone of the CX163 is varied by using the pre-set level control located above the utility zone output on the rear panel. Rotating any microphone level control fully anti-clockwise effectively turns the microphone off in that zone.
CX163 Stereo Zone Mixer Installation and Setup Guide CLOUD ELECTRONICS LIMITED 6.6 Microphone over Music priority CX163 provides facility whereby the microphone signal can be given priority over music signals in any particular zone. When a signal is detected on the mic input, all music J11 &...
CLOUD ELECTRONICS LIMITED 7.1 Utility Output The CX163 is fitted with a fixed level, balanced output for utility areas such as toilets and foyers, where it is desirable to have a fixed level signal which operates independently from the variable outputs of Zones 1&2.
Replace the top panel. Current Consumption: The CX163 can provide 90mA of power to internal equalisation modules. If this limit is exceeded, the unit will eventually overheat and then shutdown. Below is a table detailing the types of available equalisation module and their relative current consumption.
CX163 line inputs. The transformer should be mounted close to the CX163 and the unbalanced output lead should be kept as short as possible. Where both the source and destination units are earthed, it is important to isolate the primary and secondary windings to avoid a potential ground loop;...
12.4 Connecting RSL remotes to the CX163 The CX163 does not support remote source selection so is incompatible with the RSL remote series. The only remote wallplate supported by the CX163 is the RL-1 remote level plate.
Only reassemble the unit using screws identical to the original parts. In the interest of continuing improvements Cloud Electronics Limited reserves the right to alter specifications without prior notice. Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Telephone +44 (0) 114 244 7051 Fax +44 (0) 114 242 5462 E-mail: info@cloud.co.uk...