Installing AC Output Power Cables

2.2
Cable Type
A single cable
NOTE
1. UL1015 copper-core cables that can withstand 105 °C (221 °F) are recommended.
2. The table lists only the recommended cable specifications. For more information about cable
specifications, see the SUN2000-(25KTL, 30KTL)-US User Manual.
3. It is recommended that the AC output cable be routed through a pipe for protection. The maximum
pipe outer diameter allowed is 40.5 mm (1.59 in.).
1. Prepare an AC output power cable. Use hydraulic pliers to crimp the conductor part of the OT
terminal and cover the crimping area with heat shrink tubing or PVC insulation tape.
2. Remove the AC OUTPUT waterproof cable connector.
3. Route the prepared AC output power cable through the cable routing pipe.
4. Route the AC output cable and the cable routing pipe through the AC OUTPUT hole.
5. Connect the wires of the AC output cable for the SUN2000 to L1, L2, L3, and N on the AC terminal
block.
6. Secure the cable routing pipe.
2.3

Installing DC Input Power Cables

Optional DC input terminals
NOTE
Routes 1, 2, 3, 4, 5, and 6 are defined from left to right.
Cable Quantity
Four (L1, L2, L3, and N)
NOTE
1. The OT terminal screw hole specifications are M6. The
maximum specifications of cables that can be connected
are 6 AWG.
2. If heat shrink tubing is used, put it through the power cable
and then crimp the OT terminal.
Number of
Inputs
1
2
3
4
5
6
Recommended Cable Specifications
6 AWG
M6 (4 PCS)
5 N· m
NOTICE
1. The AC output power cable must be
secured to a torque that does not
exceed 6 N· m. Otherwise, the AC
terminal block may be damaged.
2. Ensure that the AC output power
cable is securely connected.
Otherwise, the inverter may fail to run
or the terminal block may be
damaged after the inverter operates.
SUN2000-(25KTL, 30KTL)-US
Connects to any one route
Connects to routes 1 and 3
Connects to routes 1, 3, and 5
Connects to routes 1, 2, 3, and 5
Connects to routes 1, 2, 3, 4, and 5
Connects to routes 1, 2, 3, 4, 5, and 6