Change De-Scale Notification Interval
Like the others, this feature is accessible only from standby (Status Light Off).
1. Press and hold harvest button for 3 seconds.
Starts the Time to Clean Adjustment State and displays the current time to clean setting.
2. Press the clean button repeatedly to cycle through the 4 possible settings:
Rev 5 and up (10/08 production start)
• 1 year (8760 hours)
• 0 (disabled)
• 4 months (2920 hrs)
• 6 months (4380 hours) (default)
Prior
• 6 months
• 5 months
• 4 months
• 3 months
3. Press Off or leave untouched for 60 seconds to select the displayed interval
Test Mode Sequence Table - Air or Water Cooled
Time (seconds)
0
30
40
50
55
70
75
85
95
On
WIV - 30 seconds
WP - 10 seconds
WP, PV, HGV - 10 seconds
HGV, Comp - 5 seconds
Comp - 15 seconds
None - 5 seconds
HGV - 10 seconds
Fan - 10 seconds
None
October 2008 Page 41
Off
WP, HGV, Comp, Fan, PV
WIV, HGV, Comp, Fan, PV
WIV, Comp, Fan
WIV, WP, Fan, PV
WIV, HGV, WP, Fan, PV
All
WIV, WP, Comp, Fan, PV
WIV, HGV, WP, Comp, PV
All – Test Complete