Figure 8.14 Component Tray
Figure 8.15 Blower Mounting Bracket
7. Unplug blower power wires. Pull blower mounting
bracket toward you and remove hose clamp and air
duct. Remove blower and attached mounting bracket
from the appliance. See Figure 8.16.
Figure 8.16 Blower Removal Through Hole in Firebox
Heat & Glo • RED40-NNN,RED40-NM, RED40-LM, RED40-NNN, RED40ST-LM, RED40ST-NM Installation Manual • 2155-975 Rev. E • 12/14
38
Figure 8.17 Fan Removal Through Firebox Bottom
8. Remove mounting bracket from blower by removing
the four screws that hold the blower to the bracket.
They are located on one side of the bracket. Save the
gasket for use with the new blower. See Figure 8.18
and Figure 8.19.
Figure 8.18 Removal of Mounting Bracket from Blower