Heat & Glo RED40-NNN Installation Manual page 35

Table of Contents

Advertisement

Optional Remote Control Receiver Location
A battery back up is not compatible with the RED40 or
RED40ST and may not be installed.
CAUTION! DO NOT install battery back up. Battery
back up is not compatible with this appliance. Battery
pack and batteries will not withstand appliance tempera-
tures.
An optional remote control receiver is available. The
optional remote control receiver must be installed in the
specifi c location under the heat shield as shown in Figure
8.6.
PLUG-IN
3V TRANSFORMER
LOW VOLTAGE
SEE NOTE 1
HIGH
TEMP
IGNITION
SWITCH
MODULE
VALVE
NEUTRAL
BATTERY PACK
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 110/1
VAC is required at junction box.
(Wire colors subject to change)
Figure 8.5 IntelliFire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Remote
Heat & Glo • RED40-NNN,RED40-NM, RED40-LM, RED40-NNN, RED40ST-LM, RED40ST-NM Installation Manual • 2155-975 Rev. E • 12/14
FLAME SPARKER/
SENSOR
(3V)
LOW VOLTAGE
SEE NOTE 1
GROUND
REMOTE
CONTROL
WIRE HARNESS
BLACK WIRE CAN BE
PLUGGED INTO ANY OF #1 - #5
LOCATIONS ON THE HOT SIDE
20
ELECTRICAL
ACCESS KNOCKOUT
REMOTE RECEIVER
Figure 8.6. Required Location of Optional Remote Control
Receiver. (Heat shield removed)
FAN
BLACK
WHITE
WIRE HARNESS
THERMO SNAP DISC
WIRE HARNESS
JUMPER WIRE
CAN BE
PLUGGED INTO
ANY OF #1 - #5
LOCATIONS
ON THE
NEUTRAL SIDE
INTERMITTENT
PILOT IGNITOR
IGNITION
MODULE
SENSOR
3 VAC
WIRE
WHITE
ORG
GROUND TO
FIREPLACE
BRN
CHASSIS
TO WALL
SWITCH WIRE
RED
OR REMOTE
JUMPER
GREEN
HIGH LIMIT
JUMPER
SWITCH
GREEN
JUMPER
VALVE
WIRES
(TO BROWN AND RED)
WALL SWITCH
WIRE ASSEMBLY
IGNI
WIR
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Red40st-lmRed40-nmRed40-lmRed40st-nnnRed40st-nm