Installer Guide; Getting Started; Typical Appliance System - Heat & Glo SL-550BE-B Owner's Manual

Table of Contents

Advertisement

4 4

Getting Started

A. Typical Appliance System
NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual
Note: Dual venting configurations
ARE NOT allowed. Appliance MUST
be vented EITHER ver tically OR
horizontally.
NON-COMBUSTIBLE ROOF FLASHING
MAINTAINS MINIMUM CLEARANCE
AROUND PIPE (SECTION 10.G)
VENT PIPE (SECTIONS 7 and 8)
CEILING FIRESTOP
ON FLOOR OF ATTIC
(SECTION 8.C)
FRAMING/HEADER
(SECTION 5.B)
GAS LINE
(SECTION 11)
Figure 4.1 Typical System

Installer Guide

VERTICAL TERMINATION CAP
(SECTION 10.I)
STORM COLLAR
(SECTION 10.H)
VENT PIPE PENETRATES ROOF
PREFERABLY WITHOUT AFFECTING
ROOF RAFTERS (SECTION 8.C)
ATTIC INSULATION SHIELD (NOT
SHOWN) MUST BE USED HERE TO KEEP
INSULATION AWAY FROM VENT PIPE IF
ATTIC IS INSULATED (SECTION 8.D)
Heat & Glo • SL-550BE-B, SL-550BE-IPI-B • 2158-900 Rev. H • 8/09
HORIZONTAL
TERMINATION CAP
(SECTION 10.L )
FRAMING HEADED OFF
IN CEILING JOISTS
(SECTION 8.C)
OPTIONAL
WALL SWITCH
MANTEL AND
MANTEL LEG
(SECTION 5.E, 13.A)
SURROUND
HEARTH EXTENSION
17