Panasonic WH-SXF12D6E5 Service Manual page 78

Air-to-water
Hide thumbs Also See for WH-SXF12D6E5:
Table of Contents

Advertisement

16.5.8. Tank Temperature Sensor Abnormality (H72)
Malfunction Decision Conditions:
When tank connection is set to ON, the temperatures detected by the tank temperature sensor are used to determine sensor
error.
Malfunction Caused:
1. Faulty connector connection.
2. Faulty sensor.
3. Faulty indoor unit PCB (main).
Abnormality Judgment:
Continue for 5 seconds.
78

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-ux12de5Wh-ux09de5Wh-sxf09d3e5

Table of Contents