The Model 21 may be installed using an all masonry fireplace built in accordance with the
Uniform Building Code and National Fire Protection Association (NFPA). The first step in
this type of installation is to determine the acceptability of fireplace and chimney for use with a
woodstove. Both construction and condition of fireplace are important
considerations when installing a woodstove. The chimney should extend at least 3' above roof
and at least 2' above any point of the roof within 10'.
REMEMBER TO HAVE YOUR CHIMNEY INSPECTED FOR LEAKS AND BLOCKAGE
BEFORE YOU INSTALL YOUR STOVE. DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
MINIMUM CLEARANCES TO FLOOR AND COMBUSTIBLES
MINIMUM CLEARANCE MASONRY INSERT
MODEL 21
A. Side Wall Combustible
B. Front Floor Protector
C. Side Floor Protector
D. Side Wood Trim
E. Top Wood Trim
F. Mantel or Brackets
1. The hearth must be of masonry construction and must extend a minimum of 16" in front of
firebox opening and a minimum of 8" to either side of the firebox opening.
(See Figure 1).
If there is not minimum hearth protection from the front of firebox opening and front of
2.
masonry hearth, a floor protector must be used in front of hearth to protect combustible
materials. The floor protector must be 3/8" minimum thickness non- combustible material
or equivalent.(See Page 5).
SECTION II
MASONRY INSERT INSTALLATION
CAUTION
25"
16"
8"
17"
17"
25"
Figure 1