GENERAL PRODUCT SPECIFICATION
6.0
Environmental characteristics
The following sections define the interference and
susceptibility condition limits that might occur
between external environment and the display device.
6.1
Susceptibility of display to external environment
Operating
Storage
6.2
Transportation tests
Standard
Drop
Test
Vibration
Test
Bump
Test
15"TFT XGA LCD CMTR
TYPE
: 150P4CG/00C
BRAND : PHILIPS
2003-01-30
YiKuan YU
2003-01-30
家电维修资料网,免费下载各种维修资料
- Temperature : 5 to 40 degree C
- Humidity
: 20% ~ 80%
- Altitude
: 0-12,000 feet
- Air pressure : 600-1100 mBAR
- Temperature : -20 to 60 degree C
- Humidity
: 5% ~ 95% ( < 40
- Altitude
: 0-30,000 feet
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35°C, Humidity less than 60 %
Philips UAN-D1400
Height
76.0 cm
1 corner
Sequence
3 faces
(-10deg C x 16 hrs)
Electrical function ok
Test
Mechanical function ok
Result
No serious damage on set appearance
(Room temp -10 C, humidity 70 %)
(1) PACKAGING
Sequence
5-200 Hz, 0.73 G, 30 min. for Each axis
(2) OPERATING
10-50-10 Hz, 0.35 mm, 30 min. for Each axis
Test
Electrical function ok
Result
Mechanical function ok
No serious damage on set appearance
For design evaluationonly
Operating
10 G, 11 msec, 1000 cycles
Temperature :
Humidity
: 60 %
Air pressure : 100 kpa
(According to DSD draft standard UAN-D636)
19
)
NSTA
76.0 cm
1 corner
3 edge
(Room temp) 6 face
23 C
8639 000 14135
590
15
75
150P4 LCD