2.4 Installation Distances and Safety Clearances

Attention! The appliance must only be operated in a horizontal position with a slope of max ± 5º.
The heater must be installed at level on a flat, stable surface, rigid enough to withstand safely the
weight of the device and not covered by any flexible material, such as carpets, plastic or fabric.
• The distance between the back of the infrared heater and the installation surface must be
at least 12.5 cm (5'') (the supplied mounting brackets provide the adequate clearance).
• At all time, the distance of your appliance from the living beings is to be min 100 cm (39").
• The distance of the heating area of your appliance from combustible materials such as curtains,
drapes, etc., must be min 100 cm (39").
• The distance of your appliance from bath tub, washbasin or other sanitary installations is
to be min 100 cm (39").
• Wall installation
- The distance of your appliance from the ground is to be min 180 cm (71").
- The distance of your appliance from the ceiling is to be min 40 cm (16") (See table 1, page 5).
- The distance of your appliance from the corners to be installed is to be min 40 cm (16").
• Ceiling installation
- The distance of your appliance from the ground is to be min 180 cm (71").
- The distance of your appliance from the ceiling is to be min 12,5 cm (5").
- The distance of your appliance from the corners to be installed is to be min 70 cm (28").

2.5 Repair and Service

• Attention! Only technical services and persons authorized by SUN may serve, repair and replace
the parts of this heater (see page 18).

2.6 UFO outdoor use

UFO-E heaters feature IP34 certificate. This IP certificate (Ingress Protection) refers that they
provide protection against large objects with diameter over 2.5mm and against water spilling from
any direction. Electrical components of UFO-E heaters manufactured in accordance
with IP34 protection class are insulated and, due to such feature, they can safely be
used in exterior environment.
UFO products without IP logo are not designed for outdoor use. Thus they should be
installed away from rain or snow.