3. Press 'Details' on the screen to viewgraphs and slot operation details, such as Battery Voltage,
Current, Temperature, Resistance etc., in a single overview. The battery icon is for switching the
view between slots.
4. Pressing the slot number button will stop the operation of the program in that slot.
· 34
In case of abnormal program termination or other ordinary error the screen will display the cause
of error and emit an audible sound.
Capacity Cut
Timer Cut
BattTemp Cut
SysTemp Too Hot
Connection Break
Input Volt Too Low
Input Volt Too Hi
Reverse Polarity
Short Circuit!
Check Voltage
Calibration Err
Fan Disconnect Err
Battery So Poor
unknown err thx
UnhandledException
MC3000
MC3000

ERROR MESSAGE

User-set capacity cut-off value has been reached. Set it higher or OFF.
User-set total time limit has been reached. Set it higher (<24h) or OFF.
User-set battery temperature has been reached. Set it higher or OFF.
Internal temperature alarm has been triggered. Stop all and cool off.
The battery connection of a busy slot got interrupted. Check the
connections.
The input voltage is below 11V. Connect proper power supply.
The input voltage is above 18V. Disconnect power and connect proper
power supply.
No such warning when a battery is connected incorrectly. Don't fool
around.
No such warning when a slot is short-circuited. Don't mess around.
Voltage of inserted battery seems off, mismatches the program for the
slot. Check BATT TYPE in your program settings. Note that the
minimum accepted voltage is 0.2V and the maximum voltage per slot
must not exceed 5.0V.
User calibration of the slot seems totally off. Perform Calibration Reset
in GSV to prevent potential damage.
The ventilation fan was supposed to start but there is no current flow.
Check connection to PCB, check fan.
Bad condition cells or batteries with high internal resistance may be
rejected.
Spontaneous extraordinary internal error of unknown origin and
magnitude, sneaky bug, thanks for your comprehension. Ignore or
unplug from mains.
§$%&ß"#wth!