SLOT OPERATION VIEW (SOV)
SysTemp
Shows the internal system temperature. Same value as seen in GSV, it serves as safety feature
for device overheat protection. At full load it can go as high as 80°C or higher and will shut down
operation thereabout. The cooling fan is controlled by this value.
Batt IR
Shows the internal battery resistance in milliOhm (1mΩ). At the start of a program, the device
always performs a quick standard test first in order to determine the internal battery resistance.
Aged or poor condition batteries have a higher IR and therefore heat up more during charge or
discharge. This measurement is fairly accurate and reproducible, yet battery contacting pressure
and battery temperature may affect it.
· 26
How to get there — In TOV, if there is at least one active slot, clicking the UP or DOWN button will
transfer to DDV.
How to exit — In DDV, pressing the ENTER button will return back to TOV. Or, after some period
of user inactivity, returns to TOV automatically.
The diagram drawing view (DDV) is a convenient way to get a quick overview of the voltage
graphs, or other graphs of relevant system quantities, over time. The scaling of both axes is
changed dynamically in order to present the data in a meaningful way. Since the horizontal axis
represents the total time, very long program durations, for example a CYCLE program with tens of
cycles, will make the diagram look funny, so for higher resolution of data and graphs the user is
advised to do some PC time with the PC Link software. During the operation of a program (SNB:
solid red) and after finishing the program normally (SNB: solid green), the displayed voltage is live
and in real time. DDV can be accessed from TOV only and there should be at least one busy or
finished slot.
The controls in DDV are as follows:
Pressing the UP or DOWN buttons will cycle through the graphs of active slots.
In DDV, SNB`s of inactive slots are not responsive.
For active slots, clicking the SNB will directly switch to its graph, whereas depressing the SNB
will fully stop the slot. The latter will make the SNB turn from solid red or solid green to blinking
red-green.
Similarly to SOV, for busy slots, pressing the STOP button (=Finish) will stop the ongoing
routine and finish the entire program at this point, prematurely. The SNB turns from solid red to
solid green. This function provides some manual interactivity and control, if ever needed.
Pressing the ENTER button (=Return) will return back to TOV.