Service Test Mode - Maytag MFD 2561HEB Technical Information

Table of Contents

Advertisement

Service Specifications
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Forced Defrost Mode:
The forced defrost function is performed using the Freezer display and Refrigerator keypad. Enter the Forced
Defrost Mode by performing the following sequence of events:
1. Open the Fresh Food door and press and hold the Door Alarm keypad
2. Press and hold Refrigerator Temperature Down keypad
3. Release the Door Alarm Keypad
Freezer
4. Press the Refrigerator Down keypad
5. Press again to force defrost Fd and SH will flash in display indicating unit is in defrost.

Service Test Mode:

The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode by
performing the following sequence of events.
1. Open the Fresh Food door and press and hold the Door Alarm keypad
2. Press and hold Refrigerator Temperature UP keypad
3. Release the Door Alarm Keypad
Freezer
4. Press the Refrigerator UP Keypad
5. Display will show 001 in left display and numeric or dashes in right display.
k
6. Press Freezer Up
Service Test – 101 Defrost Heater & Defrost Circuit
Press the Refrigerator Up
Defrost circuit. The display will read OFF when de-energized OP when energized with open defrost thermostat
and CL when energized with closed defrost thermostat.
Service Test – 102 Compressor / Condenser Fan
Press the Refrigerator Up
fan On and Off.
Service Test – 111 Fresh Food Fan (if equipped)
Press the Refrigerator Up
Off.
NOTE: Display will show state OFF or DC voltage.
16026365
!
Door
Alarm
and wait 3 seconds. FD appears in left display
Order
Replace
Fast
Reset
Vacation
Temp
Door
Filter
Mode
Alarm
Ice
Alert
again. SH appears in right display.
Door
Alarm
and wait 3 seconds.
Order
Replace
Fast
Reset
Vacation
Temp
Door
Ice
Filter
Mode
Alert
Alarm
again.
eypad
and Freezer Down
k
eypad
and Refrigerator Down
k
eypad
and Refrigerator Down
k
eypad
and Refrigerator Down
WARNING
.
Refrigerator
Max
Cool
.
Refrigerator
Max
Cool
k
eypad
to toggle through Service Test numbers.
k
eypad
k
eypad
k
eypad
4
Door
Alarm
.
Door
Alarm
.
to energize or de-energize the
to toggle Compressor/Condenser
to toggle Fresh Food Fan On and
© 2005 Maytag Services
June 2005

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfd 2561heb0Mfd 2561heq0Mfd 2561heqMfd 2561hesMfd 2561hes0Mfd 2561hew ... Show all