Error-code :
Ice Room Sensor Error
Block
①
Disassemble the FF-Ice Room Cover
②
Inspect Yellow CONNECTOR disassembly No.3(YEL)+No.4(YEL) Pin
contact/switching
③
Normal when measure resistance : 3~40KΩ Inspect the bottom WIRE
"
CONNECTOR
Main PBA
15 E
Failure : Open or
CN 78
∞
Ω
Replace the ICE MAKER
①
②
①
- 24/65 -
Back to List
Ice Room
Inspect the CONNECTOR
No.3(YEL) + Main PBA
CN78 No.10(ORG) WIRE
OPEN
Inspect the CONNECTOR
No.4(YEL) + Main PBA
CN78 No.12(S/BLU) WIRE
OPEN
Inspect the normal condition
after replace it
Measure Main PBA CN78
No.10(ORG)+No.12(S/BLU)
DC voltage with
CONNECTOR connection and
POWER ON condition
Normal : Measure DC 1.2~4
V
Failure : DC 1.3V ↓,4V↑