● Inspect self- diagnosis test

※ Fan Motor indicates failure in On condition .

Touch the Display "Energy Saver"+Alarm" Key at
the same time for 8 sec.
- After blink All LEDs, touch it until the "chime"
occurs
- Self diagnosis test is normal  check TIP 2-5
Display (Image)
(※ Must select "Power Freeze" first)
Error Item
FZ-Sensor
FF-Sensor
FZ-DEF-Sensor
FF-DEF-Sensor
Ambient-Sensor
Pantry-Sensor
Ice Maker(FZ)
-Sensor
Humidity-Sensor
Ice Maker(FF)
-Sensor
Ice Room(FF)
-Sensor
- 11/65 -
Measure
① FZ-Sensor
② Wire Open Check
① FF-Sensor
② Wire Open Check
① FZ-DEF-Sensor
② Wire Open Check
① FF-DEF-Sensor
② Wire Open Check
① Ambient-Sensor
② Wire Open Check
① Pantry-Sensor
② Wire Open Check
① Ice Maker(FZ)-Sensor
② Wire Open Check
① Humidity-Sensor
② Wire Open Check
① Ice Maker(FF)-Sensor
② Wire Open Check
① Ice Room(FF)-Sensor
② Wire Open Check