Error-code :

Ice Room Fan Motor Error

Block
Inspect Ice Room Fan
- Inspect contact CONNECTOR No.8~10 Pin/switching
Inspect Fan Motor FG output : Main PBA
rotate Fan
-
Normal : DC 2~4V,
Replace Fan
CONNECTOR
Main PBA
40 E
Failure : DC 2V↓  Wire Open Inspection 
CN 76
Back to List 
Ice Room
CN76 No.6(PNK)+1(GRY) When
※ Inspect Wire
Inspection of Fan Motor
- Inspect CONNECTOR
No.9(PNK) + Main PBA CN76
No.6(PNK) WIRE OPEN
- Inspect CONNECTOR
No.10(BLU) + Main PBA
CN76 No.2(BLU) WIRE OPEN
- Inspect CONNECTOR
No.8(BLK) + Main PBA CN76
No.1(GRY) WIRE OPEN
Inspect normal condition
after replace it
Measure Main PBA CN76
No.1(GRY) +6(PNK) DC
voltage on CONNECTOR
contact and POWER ON
condition (Ice Fan On
condition)
Normal : Measure DC 2~4 V
Failure : DC 2V↓, 4V↑