Advertisement

RE5000S
Solar
Wireless
Intruder
Alarm
System
includes:
1
Solar Wireless
x
Siren and Strobe
1
Control Unit
x
1
Passive Infra
x
Red Detector
1
Magnetic Contact
x
Detector
1
Remote Control
x
1
Power Supply
x
INSTALLATION & OPERATING
INSTALLATION & OPERATING
PROFESSIONAL
alarm systems
HANDBOOK
HANDBOOK
professional

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RE5000S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Response Alarms RE5000S

  • Page 1 RE5000S professional Solar Wireless Intruder Alarm System includes: Solar Wireless Siren and Strobe Control Unit Passive Infra Red Detector Magnetic Contact Detector Remote Control Power Supply INSTALLATION & OPERATING INSTALLATION & OPERATING HANDBOOK HANDBOOK PROFESSIONAL alarm systems...
  • Page 2: Safety Warnings

    FOREWORD SAFETY WARNINGS Your decision to purchase an RE5000S Remote Control Wireless Intruder Alarm System represents a Before proceeding with the installation, please note major and sensible step towards total protection of the following safety warnings: your premises, its contents and its occupants.
  • Page 3: Table Of Contents

    PROGRAMMABLE FUNCTIONS (cont) Exit Delay Time Alarm Autostop Time INTRODUCTION & OVERVIEW Main User Access Code Door-Chime Zone EXTENDING THE RE5000S SYSTEM Entry Delay Time Part Arm Zone Omit PLANNING AND EXTENDING YOUR Exit Delay Tone WIRELESS ALARM SYSTEM Quick Arm/Part Arm...
  • Page 4: Introduction & Overview

    INTRODUCTION & OVERVIEW The RE5000S Alarm System is designed to allow Remote Control Unit(s) for use by other members of flexibility in configuring and using the system. The your household. Full details of other accessories to Detectors can be set to operate on any one of 6 extend your system are given on pages 27 and 28.
  • Page 5 Communicator (fitted in the Control Unit (RE5000M) Wiring Interface and the Siren & Strobe) Also included:- Installation and operating manual All necessary fixings Wireless Remote Detector and Remote Control (RE5000R) Window warning stickers Control Alkaline Batteries RE5000S Professional Alarm System...
  • Page 6: Planning And Extending Your Wireless Alarm System

    PIR’s and Magnetic Contact Detectors as bedroomed house. Just add additional detectors and when you require. The RE5000S Alarm System where further protection is needed. Each property will have its own layout, the diagram shown is intended as a guide.
  • Page 7: Control Unit

    13A socket, or fused connection unit. each day. Note: Ensure that the adaptor will not be removed from the socket or accidentally switched off, when the system is in use. RE5000S Professional Alarm System...
  • Page 8: Installation

    An in-line DC Mains Adaptor and Cable are supplied If the colours of the wires in the mains lead do with the Control Unit. To connect the Mains Adaptor not correspond with the markings identifying View inside Terminal/Battery Compartment RE5000S Professional Alarm System...
  • Page 9: Back-Up Battery

    The Back-up Battery is especially in the centre ‘o’ position. Use the tip of a ball point capable of providing emergency power to the Control pen or a small screw driver to move each switch in turn. RE5000S Professional Alarm System...
  • Page 10: Remote Control(S)

    REMOTE CONTROL(S) One Remote Control Unit is supplied in the standard 1. Remove the fixing screw from the back of the RE5000S package. However, additional Remote Remote Control Unit and carefully separate the Control Unit(s) can be purchased separately, if two halves of the unit.
  • Page 11: Setting The Control Unit To Test Mode

    However, if you wish to exit the Test mode, press and Smoke Detectors and RE5000MP Medical Alert hold the button until the unit emits 2 bleeps and Pendant respectively. These devices cannot be the Arm/Part Arm LED’s extinguish. assigned to different Zones. RE5000S Professional Alarm System...
  • Page 12: Wireless Passive Infra Red Detector(S)

    One Passive Infra Red Detector is supplied in the 4. Where possible, mount the Detector such that standard RE5000S package. However, additional the logical path of an intruder would cut across Passive Infra Red Detectors can be purchased the fan patterns rather than directly towards the separately, if required.
  • Page 13: Mounting

    3. Once the detection range has been verified, refit 5. Screw the wall bracket to the wall using the the battery cover ensuring that the battery lead screws supplied. wires are not trapped in the process. RE5000S Professional Alarm System...
  • Page 14: Fitting The Standard Magnetic Contact Detector(S)

    MAGNETIC CONTACT DETECTOR(S) One standard Magnetic Contact Detector is supplied in the RE5000S package. However, additional Magnetic Contact Detectors can be purchased separately if required. Any number of Magnetic Contact Detectors can be used with your system providing they are all coded with the system ‘House Code’...
  • Page 15: Installing And Setting The External Solar Wireless Siren & Strobe

    Where applicable, the Solar Siren & Strobe should be positioned a minimum of twice the width of the eaves overhang below the eaves. Remember that in winter the sun is lower in the sky and you should avoid winter shadows where possible. RE5000S Professional Alarm System...
  • Page 16: Installation

    1-8 to a random sequence of ‘ON’s’ and ‘OFF’s’. the rechargeable battery to the charging leads red to Make a note of the Siren Code dip switch settings as red (+) and black to black (-). RE5000S Professional Alarm System...
  • Page 17: Programmable Functions

    - Press Access Code (the code that operates the system) of For example: For House Code:- To enter the Programming mode and change each programmable function, proceed as follows:- Enter or Current Main User Access Code RE5000S Professional Alarm System...
  • Page 18: Instant/Delay Zone

    A Zone LED will illuminate to indicate the setting:- Note: a separate Second User Access Code is also Factory default:- available which will allow only Arming/Disarming at the Control Unit. You may therefore wish to allow 30 seconds - Zone 3 LED ‘ON’. RE5000S Professional Alarm System...
  • Page 19: Door-Chime Zone

    Zone LED. of the Zone to illuminate or extinguish the appropriate Zone LED. Press to memorise the setting and to revert to the Programming mode. Press to memorise the setting and to revert to the Programming mode. RE5000S Professional Alarm System...
  • Page 20: Exit Delay Tone

    ALERT PENDANT CODE) A small radio transmitter is incorporated within the Press to select Quick ARM ‘ON’ RE5000S Control Unit to operate and control the Press to select Quick ARM ‘OFF’ external Solar Siren & Strobe. To enable the Control Unit to communicate with the external...
  • Page 21: Second User Access Code

    Disarming only at the Control Unit and may Full details of the Control Unit terminal block therefore be entrusted to children, guests or connections and Communicator Interface Cable neighbours; or alternatively this code could be connection are shown overleaf:- RE5000S Professional Alarm System...
  • Page 22: Operating Instructions

    Re-Arm. Failure to do so will Communicator Interface cause a full alarm if any protected door is opened or Cable Connection movement is detected by a Passive Infra Red Detector. RE5000S Professional Alarm System...
  • Page 23: Part Arming The System

    Second User Code) followed by The Control Unit will initiate a full alarm and Zone 8 Note: If the system is not disarmed during the Entry LED will flash. Delay Period a full alarm will occur. When using the RE5000S Professional Alarm System...
  • Page 24: Battery Monitoring

    Detector. If the LED is dim or does not illuminate, the Remote Control to de-activate. Clear the Control Unit battery needs to be replaced. In the event of a low ‘Alarm Activated’ light by entering your Main User or RE5000S Professional Alarm System...
  • Page 25: Maintenance

    MAINTENANCE RECHARGEABLE BATTERIES Your RE5000S Intruder Alarm System requires very The rechargeable batteries in the Control Unit and little maintenance. However, a few simple tasks will Solar Siren & Strobe have a typical life of 4 years and ensure its continued reliability and operation.
  • Page 26: Trouble Shooting

    4. Check that battery covers on all detectors are fitted 2. Siren & Strobe has not received ‘Stop’ signal. securely. Press Disarm on Remote Control to make the Control Unit re-transmit the ‘Stop’ signal. 5. Check for Jamming Detection Alarm operation. RE5000S Professional Alarm System...
  • Page 27 1. Low battery - replace alkaline battery. Check battery cover lugs are not broken. IF YOU HAVE ANY PROBLEMS RING THE HELPLINE: 09062 777200 (Lines open 9.00am to 6.00pm, Monday to Friday. Calls charged at 25p per minute) RE5000S Professional Alarm System...
  • Page 28: Alarm Record

    Medical Pendant(s) Use the above diagrams to record your ‘House Code’ and ‘Siren Code’, eg., Purchase date Installation date Control Unit serial number This information is highly confidential and should be kept in a very safe location. RE5000S Professional Alarm System...
  • Page 29: Extending Your Re5000S Professional Wireless Alarm System

    RE5000SS Additional Solar Wireless Siren & Strobes can be added to your RE5000S Professional Solar Wireless Alarm System to give a higher level of security. For example you could have a Siren & Strobe fitted to the front and rear of your premises.
  • Page 30 There is no limit to the number of Wireless Smoke Detectors you can use with your system and when used with the RE5000S Control Unit a separate Zone/Alarm output is activated and a Fire Alarm siren tone is sounded to identify that a fire signal has been received by the Control Unit.
  • Page 31: Your Guarantee

    For security, Recorded or Registered Post is recommended. Service Department, Response Electronics Plc Longmead Business Centre, Blenheim Road Epsom, Surrey KT19 9QQ Response RE5000S Professional Alarm System...
  • Page 32 Mastercard Visa Delta Switch Solo - the sum of £79.95. Issue Number Start Date Expiry Date 2. I enclose my cheque postal order (Switch Only) for £79.95 made payable to Response Electronics Plc. Signature Date Response RE5000S Professional Alarm System...
  • Page 33 FREE ENTRY FREE ENTRY INTO INTO PRIZE DRAW PRIZE DRAW TO WIN A FANTASTIC PRIZE TO WIN A FANTASTIC PRIZE (See the enclosed Prize Draw Offer Sheet for the current offer, plus Prize Draw Rules) Either fill in your details overleaf and return the GUARANTEE REGISTRATION FORM WITH ENCLOSED...
  • Page 34: Remote Control

    RE5000S PROFESSIONAL SOLAR WIRELESS ALARM SYSTEM - SPECIFICATION Control Unit Wireless Passive Magnetic Contact Infra Red Detector Detector (with hard-wired inputs) Order Code: RE5000P Order Code: RE5000MHW Response Electronics Plc are Quality Assurance Registered to BS EN ISO9002 1994, 6 Fully Programmable Zones by SGS Yarsley ICS.

Table of Contents