The Menus; Access To The Menus; Memorised Data; Status - Hawker Life IQ Technical Manual

Single phase and 3-phase chargers
Table of Contents

Advertisement

THE MENUS

The menus provide access to the following functions:
Last 200 charging cycles ( Memorisations menu).
Viewing of faults, alarms, etc. ( Status menu).
Download of data stored in the charger via the USB storage
memory.
Charger configuration ( Configuration menu).
Setting of date, language and others ( Parameters menu).
Management of password ( Password menu)
Viewing basic information, type of charger ( Information menu)

ACCESS TO THE MENUS

Functions of the keys
To access the menu, press the key

MEMORISED DATA

Displays historical data from the last 200 charging cycles.
The MEMO 1 refers to the latest record.
Display an history
Proceed as follows:
1.
Select a record with
or
2.
View the first screen by pressing
3.
View the successive lines by pressing
4.
Return to previous screen by pressing

STATUS

This menu displays the charger's internal counters (number of normal
charges, faults by type, etc.)
Information displayed
Reset information of this screen is done via the Configuration menu.
Indication
Information
Number of complete charges.
Number of incomplete charges.
EGAL
Number of automatic equalisation
charges carried out by the charger.
TH
Number of temperature faults*.
DF1, etc.
Number of faults an types 1, 2, 3, 4, 5
or fault pump*.
(*): see § Fault codes

USB

This menu provides access to the USB function. The charger can store
charging data in a USB memory.
Record Memo
Enables the storage of charge Memorisations and the Status data. The
file, in CSV format (useable with Memoreport PC or Excel), will be stored
in the USB stick under the name:
MDDDHHMM.CSV with
M
: for Memorization
DDD : Day of the year
HH
: Hour of file creation
MM
: Minute of file creation
Eject
For safe removal of the USB stick without damaging the data file.

CONFIGURATION

This menu allows to configure the charger.
for 3 seconds.
006
.
.
.
.
Battery
Auto/Manu capacity
The charger can estimate the capacity of the connected battery (Auto)
or the user can determine the capacity (Manu) via the Capacity menu.
Capacity
Determines the battery capacity for an optimised charge (Manu)
Temperature
Defines the battery temperature when the charge is started.
This parameter adjusts the regulation voltages on the charging profile
(values between –15°C and 65°C).
Without Wi-IQ
®
: defines the average operating battery temperature
before the charge.
With Wi-IQ: the battery operating temperature will be automatically
defined. It is recommended to enter the observed average
temperature, especially in cold areas. The battery temperature will
be analysed during the charge; if it increases too much, the charger
will stop to prevent any possible damage.
High temperature
Defines the safety limit in high temperatures.
Without Wi-IQ: not used.
With Wi-IQ: If the battery temperature, during the charge, reaches
the programmed limit, the charger will stop the charge and wait
until the temperature decreases.
Charge
Profile
For selecting the right charging profile for the battery:
ionic, gel, pneumatic, PzM (Water Less
Hawker XFC
TM
With Wi-IQ: the selection of the profile will be automatic and
the charger will recharge the battery with the appropriate profile
whatever profile has been selected.
AutoStart
Default is ON, so the charge will start as soon the battery is connected
to the charger. If Autostart is OFF, the charge will start only if the central
button is pressed.
Delayed start
Defines:
Either the charging start deadline
Or the charging start hour.
This delay enables the charger to be used during off-peak when the
electricity is at lower tariffs. Note: the charger doesn't manage the
summer/winter time changes.
Conditional charge
The charger will only commence the charge if the battery has reached
the limit of depth of discharge of more than x%. For example if the user
wants to charge the battery only if it is discharged more than 30%, the
parameter 30 has to be entered in the conditional charge. The 0 value
disables the function.
Floating voltage
Setting a floating voltage at the end of charge to compensate eventual
consumption by the truck (AGV type). The parameter voltage determines
the floating voltage at the end of the charge. The parameter Current
defines the average current consumed by the truck electronics (crucial
for currents at the end of charge).
Maximum current
This manually decreases the maximum output current of the charger.
Equalisation
These parameters are not valid for GEL and Hawker XFC
Manu Current
This defines the equalisation or desulphation current for a manual start.
Time
Sets the equalisation time from 1 hr to 48 hrs
Delayed start (delay)
Sets the delay between the normal charge and the equalisation charge
from 0 hr to 23 hrs.
Frequency
Selects one or several periods for carrying out the equalisation charge.
The user can select one or several days per week.
Refresh
Default is ON, (only for the IONIC profile) the refresh charge after the
main charge maintains the battery in good condition by adding some
pulse after the main charge. If the refresh is OFF, the refresh charge is
disabled, but the equalization charge is still operating as defined on the
previous menu.
5
®
) WL20 (Water Less
®
20),
TM
batteries.