4

Connecting the plug-in connections and earth cables

.15
● Connect all plugs as labelled on the control box 1
● In the case of control unit EcoDrive P74 ED-L the adapter cable X2 is to be connected to
● The following ground cables must be attached in order to discharge static electricity.
● Connect the earth cable from the superstructure (480 mm)to the earthing connection A.
● Join earthing connection A andearthing connection B with the earth cable (700 or 100 mm).
● Connect the earthing connection on the motor base with earthing connection A with the
● On control P74 ED-L connect main switch and earthing connection A with the earth cable
● Fasten the earth cable from plug X1 to earth point B.
26
EcoDrive P74-ED-L
B
X4
1
Fig. 6 - 06
socket X2. Plug X2.1 is to be connected to the motor and plug X2.2. to the synchronizer.
earth cable (700 mm)
(500 mm).
X1
X2
X3
X7
X6
X5
A
M6x16
X2
X2.1
X2.2