Msz-Ga50Va Muz-Ga50Va; Msz-Ga60Va Muz-Ga60Va; Msz-Ga71Va Muz-Ga71Va; Cool Operation - Mitsubishi Electric MSC-CA20VB Service Technical Manual

Table of Contents

Advertisement

MSZ-GA50VA MUZ-GA50VA

MSZ-GA60VA MUZ-GA60VA

MSZ-GA71VA MUZ-GA71VA

WIRELESS REMOTE CONTROLLER
Signal transmitting section
Operation display section
Once the operation mode is set, the same operation mode can be repeated by simply turning OPERATE/STOP
(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to protect system from overload and compressor will not
restart for 3 minutes.
6-13. COOL (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button)to select the desired temperature.
The setting range is 16 ~ 31°C
1. Thermostat control
Thermostat is ON or OFF by difference between room temperature and set temperature
Room temperature minus set temperature : -1.0 : or more··············································ON
Room temperature minus set temperature : less than -1.0 :············································OFF
OPERATE /STOP
(ON /OFF)button
FAN SPEED CONTROL button
OPERATION SELECT button
ECONO COOL button
LONG button
RESET button
Initial temperature difference
TOO
TOO
ON/OFF
WARM
COOL
TEMPERATURE buttons
Indication of remote controller
model is on back.
WIDE VANE button
(Vertical vane button)
OFF-TIMER button
ON-TIMER button
TIME SET buttons
FORWARD button
LONG
BACKWARD button
CLOCK SET button
VANE CONTROL button
(Horizontal vane button)
86
Difference between room
temperature and set temper-
ature during operation.
Set temperature
Thermostat
:
-1.0
-0.7
: