Ms Microprocessor Control; Ms-Ga50Vb Mu-Ga50Vb; Ms-Ga60Vb Mu-Ga60Vb; Ms-Ga80Vb Mu-Ga80Vb - Mitsubishi Electric MSC-CA20VB Service Technical Manual

Table of Contents

Advertisement

2

MS MICROPROCESSOR CONTROL

MS-GA50VB MU-GA50VB

MS-GA60VB MU-GA60VB

MS-GA80VB MU-GA80VB

WIRELESS REMOTE CONTROLLER
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
• The following indication applies regardless of
shape of the indicator.
Operation Indicator
Indication
Operation state
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait until the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Signal transmitting section
Operation display section
OPERATE/ STOP
(ON/ OFF) button
ON/OFF
ON/OFF
VANE button
(Horizontal vane button)
I FEEL COOL
FAN
DRY
MODE
OPERATION SELECT button
ECONO COOL
ECONO COOL button
WIDE VANE button
(Vertical vane button)
RESET button
Lighted
Not lighted
Difference
between target
temperature
and room
temperature
Approx.
2 : or more
Approx.
2 : or less
PM
AM
TOO
TOO
WARM
COOL
TEMPERATURE buttons
CLOCK
PM
AM
TOO
TOO
WARM
COOL
FAN SPEED CONTROL button
FAN
STOP
OFF-TIMER button
VANE
START
ON-TIMER button
WIDE VANE
HR.
HR. button
MIN. button
LONG
MIN.
(TIME SET button)
RESET CLOCK
CLOCK SET button
LONG button
Once the operation mode is set, the same operation mode can
be repeated by simply turning OPERATE/STOP (ON/OFF) but-
ton ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
2-1. "I FEEL CONTROL" (
(1) Press OPERATE/STOP (ON/OFF) button on the remote
controller. OPERATION INDICATOR lamp of the indoor
unit turns on with a beep tone.
(2) Select "I FEEL CONTROL" mode with OPERATION
SELECT button.
(3) The operation mode is determined by the room tempera-
ture at start-up of the operation.
Initial room temperature
25: or more
more than 13:,
less than 25:
15
) OPERATION
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"

Advertisement

Table of Contents
loading

Table of Contents