Specifications - Panasonic CS-CE9LKE Service Manual

Hide thumbs Also See for CS-CE9LKE:
Table of Contents

Advertisement

2 Specifications

MODEL
Performance Test Condition
Power Supply
Capacity
Running Current
Input Power
Annual Consumption
EER
Power Factor
Indoor Noise (H / L)
Outdoor Noise (H / L)
Capacity
Running Current
Input Power
COP
Power Factor
Indoor Noise (H / L)
Outdoor Noise (H / L)
Low Temp. : Capacity (kW) / I.Power (W) / COP
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
Max Current (A) / Max Input Power (W)
Starting Current (A)
Type
Compressor
Motor Type
Output Power
Type
Material
Motor Type
Input Power
Output Power
Lo
Speed
Me
Hi
INDOOR
OUTDOOR
Phase, Hz
V
kW
BTU/h
Kcal/h
A
W
kWh
W/W
Kcal/hW
%
dB-A
Power Level dB
dB-A
Power Level dB
kW
BTU/h
Kcal/h
A
W
W/W
Kcal/hW
%
dB-A
Power Level dB
dB-A
Power Level dB
W
W
W
Cool/Fan
rpm
Heat
rpm
Cool/Fan
rpm
Heat
rpm
Cool/Fan
rpm
Heat
rpm
CS-CE9LKE
CU-CE9LKE
EUROVENT
Single, 50
Min.
Mid.
0.60
2.50
520
2150
125
4.80
4.59
4.16
3.94
39 / 25
55 / 42
46 / -
61 / -
0.60
3.40
520
2920
120
5.00
4.59
4.33
3.95
40 / 27
56 / 43
47 / -
62 / -
3.62 / 1.19k / 3.04
3.05 / 1.27k / 2.40
6.0 / 1.34k
Hermetic Motor
Brushless (4-poles)
Cross-flow Fan
ASG20K1
Transistor (8-poles)
1015
1120
1230
5
230
Max.
3.00
2580
2.6
545
750
273
4.00
3.44
91
5.00
4300
3.5
740
1.34k
3.73
3.21
92
3.5
750
47
40
750
800
935