Wiring - Carrier 42TSV052P1 Installation Manual

Hide thumbs Also See for 42TSV052P1:
Table of Contents

Advertisement

Install the drain joint of the outdoor unit
Fit the seal into the drain joint, then insert the drain joint into the
base pan hole of outdoor, rotate 90° to securely assemble them.
Connect the drain joint with an extension drain hose (Locally
purchased), in case of the condensate draining off the outdoor
unit during the heating mode.
Seal
Drain joint
The base pan
of outdoor unit
All the pictures in this manual are for explanation
purpose only. They may be slightly different from the
air conditioner you purchased(depend on model).The
actual shape shall prevail.

10. WIRING

The appliance shall be installed in accordance with
national wiring regulations.
The air conditioner should use separate power supply
with rated voltage.
The external power supply to the air conditioner should
have ground wiring, which is linked to the ground wiring
of the indoor and outdoor unit.
The wiring work should be done by qualified persons
according to circuit drawing.
An all-pole disconnection device which has at least 3mm
sepaaration distance in all pole and a residual current
device (RCD) with the rating of above 10mA shall be
incorporated in the fixed wiring according to the national
rule.
Be sure to locate the power wiring and the signal wring
well to avoid cross-disturbance.
Do not turn on the power until you have checked
carefully after wiring.
The power cord type designation is H07RN-F.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
installation manual
14
The base pan hole
of outdoor unit
Seal
Drain
joint
Fig.9-1
NOTE
Remark per EMC Directive 2004/108/EC
For to prevent flicker impressions during the start of the
compressor
(technical
conditions do apply.
1
The power connection for the air conditioner has to be
done at the main power distribution. The distribution has
to be of a low impedance, normally the required
impedance reaches at a 32 A fusing point.
2
No other equipment has to be connected with this power
line.
For detailed installation acceptance please refer to your
3
power supplier, if restrictions do apply for products like
washing machines, air conditioners or electrical ovens.
For power details of the air conditioner refer to the rating
4
plate of the product.
For any question contact your local dealer.
5
Connect the cable
10.1
Dissemble the bolts from the cover.(If there isn't a cover on
the outdoor unit, disassemble the bolts from the maintenance
board, and pull it in the direction of the arrow to remove the
protection board.)
(Refer to Fig.10-1)
Connect the connective cables to the terminals as identified
with their respective mached numbers on the terminal block
of indoor and outdoor units.
Re-install the cover or the protection board.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper tube.
Protection board
All the pictures in this manual are for explanation
purpose only. They may be slightly different from the
air conditioner you purchased(depend on model).The
actual shape shall prevail.
NOTE
process) following
installation
Cover
Fig.10-1
NOTE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents