Sanyo SAP-KCRV243GJH Technical & Service Manual page 72

Table of Contents

Advertisement

HIGH POWER
Raises the power but remains in the same operating mode.
This function is set with the HIGH POWER button on the
remote controller.
(It is set regardless of the temperature and fan speed
settings.)
HIGH POWER operation from the remote controller
The unit operates at maximum output for 15 minutes.
regardless of the desired temperature.
The fan speed is 1 step above "High."
Frequency
MAX
0
15min. 5min.
Start
NOTE
When HIGH POWER operation ends, the unit operates at
low Hz for 5 minutes, regardless of the thermostat OFF
conditions.
When in DRY mode, operation is in the cooling zone.
When in HEAT mode, defrosting dose not occur during
HIGH POWER operation.(only cool type unit without this
mode)
If HIGH POWER is set while defrosting is in progress,
HIGH POWER operation begins after defrosting ends. (it
is not appropriate for only cool type unit)
HIGH POWER operation cannot be set from the remote
controller when the unit is stopped.
HIGH POWER operation and ECONOMY operation
cannot be used at the same time. The function set last
takes priority.
ECONOMY
When ECONOMY operation is set, the temperature and
fan speed settings will be adjusted automatically to allow
comfortable sleep.
When ECONOMY operation is set "
the remote controller.
COOL and DRY modes
The indoor unit fan speed is automatically lowered
for quiet operation.
The temperature setting is raised by 1˚C one hour
after ECONOMY operation is set.
HEAT mode
The indoor unit and outdoor unit fan speeds are
automatically lowered for quiet operation.
The temperature setting is lowered by 3˚C one hour
after ECONOMY operation is set.
In addition, the temperature setting is lowered by
4˚C after two hours have passed.
(only cool type unit without this mode.)
Time
End
mark" appears on
Lamp colors
Operation lamp
HEAT operation
: Red
DRY operation
: Orange
COOL operation
: Green
TIMER lamp
: Green
ON timer operation
Operation starts when the time set for the ON timer is
reached. When a time is set, the TIMER lamp illuminates.
The below comfort timer programming is performed.
A comfort time is calculated from the set temperature and
the room temperature, either 60 minutes prior or 30
minutes prior to the set ON timer time, and operation is
started in advance of the set ON time. (The indoor fan
speed is "Medium.")
[COOL]
Indoor temperature-Set temperature = Temperature
difference
[HEAT]
Set temperature-Indoor temperature = Temperature
difference
Temperature difference(˚C)
12<Temperature difference
6 < Temperature difference
NOTE
This function does not operate if the ON timer standby
time is less than 30 minutes.
OFF timer operation
Operation stops when the time set for the OFF timer is
reached.
When a time is set, the TIMER lamp illuminates.
Timer backup
If the indoor unit is unable to receive the timer time-end
signal when the ON or OFF time is reached, then timer
time-end occurs according to the indoor unit backup timer
within approximately 26 minutes.
Operation stops if there are no operator controls for 25
hours or longer after unit operation switched from OFF to
ON by use of ON timer operation.
69
Advance start time (min.)
60
30