5. APPENDIX
Service Maintenance Guide
Symptom(s)
1 or more LED's are
not illuminating
Device has no power
Fixture is not
responding to DMX
Loss of signal
Stand alone
operation
The display is only
showing: ####
Possible Solution(s)
Clean the fixture regularly to avoid any such failure. This fixture is
convection cooled, which means that if the surface is kept clean
and free of debris, then proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event,
all of the red, green, or blue in a single module will no longer
illuminate. This does not mean that all of the LEDs have failed,
but the circuit is wired in series.
An LED may have failed, resulting in a short circuit. In this event, only
the single LED which has failed will no longer function. This does not
mean that all of the LEDs have failed, but the circuit is wired in series.
-Note: In the event of LED failure, a replacement LED PCB
assembly may be purchased directly from Our company
Check for power on Mains
-Note: In the event of autoswitching transformer failure, the unit
can be sent in for repair; however, a replacement part can be
ordered directly from Our company
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections
Call service technician
-Note: In the event of Display PCB failure, a replacement PCB
can be ordered directly from Our company
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables or black lights
This fixture has built-in, automatic programs that may be
triggered from the onboard Control Board
The password lockout has been enabled. you can use the
password: { MODE UP MODE DOWN MODE UP
MODE DOWN }