8.4 Terminal Problems

Terminal does not respond to key press while the display stays on
Message "Can' find AP..." is shown when you try to start a program
 There is no user's application program for PA-20 / PA-20 loaded in the terminal. Contact
your supplier.
For example pressing the SFT key does not toggle the char input indicator
 There is a flaw in the application program. Retrieve the battery pack and place it in again.
Activate the system menu and restart the application program, or download new
application.
 If problem appears continuously, contact the user's application program supplier.
CCD scanner stays off, when pressing the Scan key
Power is off
 The Scan key is not the power key. Press the PW key to get power first.
 If the terminal is not used for a while, the terminal will automatically switch off. Press
any key to reactivate the terminal.
Terminal gets no power, when pressing the power key
The main battery is exhausted
 Replace the battery pack, or charge the terminal n the cradle.
Terminal is still not workable and needs a service
Send the terminal to your local supplier for service, paying attention to the limited warranty.