Sony CCU-TX7 Service Manual page 28

Camera control unit camera operation unit cou-tx7 sdi output board dxbk-701
Hide thumbs Also See for CCU-TX7:
Table of Contents

Advertisement

. INTERCOM/TALLY (D-Sub 25P, FEMALE)
13
25
(EXTERNAL VIEW)
No.
Signal
1
GREEN TALLY (Y) IN ON : 24 V DC/TTL (H)/SHORT
14
GREEN TALLY (X) IN OFF : 0 V DC/TTL (L)/OPEN
2
RED TALLY (Y) IN
15
RED TALLY (X) IN
3
GND
16
CAM MIC OFF IN
4
CH2 INT IN
17
CH1 INT IN
5
4W CH2 (R) (G) OUT
18
4W CH2 (R) (Y) OUT
6
4W CH2 (R) (X) OUT
19
4W CH2 (T) (G) IN
7
4W CH2 (T) (Y) IN
20
4W CH2 (T) (X) IN
8
2W CH2 (G) IN/OUT
21
2W CH2 (X) IN/OUT
9
4W CH1 (R) (G) OUT
22
4W CH1 (R) (Y) OUT
10
4W CH1 (R) (X) OUT
23
4W CH1 (T) (G) IN
11
4W CH1 (T) (Y) IN
24
4W CH1 (T) (X) IN
12
2W CH1 (G) IN/OUT
25
2W CH1 (X) IN/OUT
13
CHASIS GND
2-2
1
14
(0 dBu = 0.775 Vrms)
Specifications
ON : 24 V DC/TTL (H)/SHORT
OFF : 0 V DC/TTL (L)/OPEN
GND for INTERCOM REMOTE
L: CAM INCOM MIC OFF
L: CH2 INTERRUPT ON
L: CH1 INTERRUPT ON
4W CH2 SYSTEM RECEIVE
0 dBu BALANCED
4W CH2 SYSTEM TALK
0 dBu BALANCED
2W CH2 SYSTEM 0 dBu
Recommended Term. imp.= 600 Z
4W CH1 SYSTEM RECEIVE
0 dBu BALANCED
4W CH1 SYSTEM TALK
0 dBu BALANCED
2W CH1 SYSTEM 0 dBu
Recommended Term. imp.= 600 Z
. RS-232C CH1/CH2 (D-Sub 25P, FEMALE)
13
25
(EXTERNAL VIEW)
No.
Signal
Specifications
1
CHASSHIS GND
This is based on RS-232C
2
TXDATA
specification.
3
RXDATA
38,400 bps or 9600 bps Switchable
by the internal switch on the
4
RTS
CT-181 board of CCU.
5
CTS
6
DSR
7
GND
20
DTR
. REMOTE (10P FEMALE)
7
6
(EXTERNAL VIEW)
No.
Signal
1
(SPARE)
2
RM VIDEO OUT (X)
*
*
3
RM VIDEO OUT (G)
S. DATA (RCP → CCU)
4
5
S. DATA GND
6
S. DATA GND
S. DATA (CCU → RCP)
7
8
(SPARE)
9
POWER +12.5 V DC GND
10
POWER +12.5 V DC OUT
* : The units with the following Serial Nos. output the RM video out signal.
Serial No. 13016 and higher (UC)
Serial No. 42930 and higher (CE)
1
14
(0 dBu = 0.775 Vrms)
8
1
2
10
9
3
5
4
Specification
VBS, 1.0 V p-p
RX DATA equivalent
communication rate that is
based on RS-232C
specification is 38,400 bps.
TX DATA equivalent
communication rate that is
based on RS-232C
specification is 38,400 bps.
GND for +12.5 Vdc
10.6 V to 17.0 Vdc
CCU-TX7 (E)/V1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccu-tx7p

Table of Contents