2-6. SWITCH FUNCTIONS ON BOARD

CT-181 board
TP2006
CT-181
S2011
R TALLY
R TALLY
CONTACT
CONTACT
TP1000
POWER
POWER
DC24V
DC24V
S2013
E1000
TTL
TTL
R TALLY
G TALLY
CONTACT
CONTACT
S2012
POWER
G TALLY
POWER
DC24V
DC24V
S2014
TTL
G TALLY
TTL
MIC GAIN
MIC 1 GAIN
SW1000
NORM
CH-1
MIN
MAX
SW1001
MIC 2 GAIN
NORM
CH-2
S1001
MIN
MAX
PANEL
SELECT
PANEL
REMOTE
LOCAL
CONTROL MODE
NORM
NORMAL
CONT MODE
SLAVE
SLAVE
S1002
. S1000
This switch is for the adjustment in the factory.
Factory setting : All OFF
. S1001 (PANEL REMOTE/LOCAL)
When the RCP or COU is connected, the connected one is
selected in spite of PANEL setting.
Also, when both RCP and COU are connected, RCP or
COU is selected according to the PANEL (REMOTE/
LOCAL) setting.
Factory setting : REMOTE
Note :
RCP : Remote Control Panel
COU : Camera Operation Unit COU-TX7
. S1002 (CONTROL MODE NORMAL/SLAVE)
The RCP is only connected or both RCP and COU are
connected and then the S1001 switch is set to REMOTE
side. In this case, the RCP is valid, and this S1002 switch
is invalid. The COU is only connected or both RCP and
COU one connected, and then the S1001 switch is set to
LOCAL side. In this case, the COU is valid, and this S1002
switch is used as follows ;
NORMAL : COU can be used
SLAVE
: The operation of CCU can be used.
COU can not be used.
Factory setting : NORMAL
. S1004
This switch is used to change the RS-232C and IF BOARD.
Factory setting : RS-232C side
CCU-TX7 (E)/V1
E1001
RET FREQ
CV1
E12
RF AGC DLY
RV22
PROMPT FREQ
RV23
PROMPT TUNE
PROMPT LEVEL
LV3
E13
TP22
S2002
CN7
PROMPT
RX
TX
S1004
CN8
RS232C-2
PROMPT RF RX
IF BOARD
TP1001
TP2001
E16
TP2003 TP2002 TP2004
TP2005
CT-181 Board
(A SIDE)
RCP-TX7
. S2002 (PROMPT SELECT TX/RX)
TX : When selecting the TX mode, the CCU modulates
the VBS signal input to the PROMPT VIDEO IN
connector on the CCU-TX7/TX7P, and modulated
signal is sent to the CA-TX7/TX7P.
RX : When selecting the RX mode, the CA modulates
the VBS signal input to the PROMPT VIDEO IN
connector on the CA-TX7/TX7P, and modulated
signal is sent to the CCU-TX7/TX7P.
Note : When using this switch, change as follows.
. In case of using the TX mode (TX side) ;
1) Disconnect CN8 and connect CN3 and CN7
on the CT-181 board.
2) Set S1 and S6 switches to "PROMPTER" side
on the YD-25 board of CA-TX7/TX7P.
. In case of using the RX mode (RX side) ;
1) Disconnect CN7 and connect CN3 and CN8
on the CT-181 board.
2) Set S1 and S6 switches to "AUX" side on the
YD-25 board of CA-TX7/TX7P.
Factory setting : TX
. S2011 (R TALLY POWER/CONTACT)
. S2013 (R TALLY DC24 V/TTL)
These switches are set according to the signal standard of
the R TALLY signal input to the INTERCOM/TALLY/
PGM connnector on the CCU rear panel. For the relation
between the signal and switch setting, refer to the table below.
Factory setting : (S2011) POWER
(S2013) DC 24 V
. S2012 (G TALLY POWER/CONTACT)
. S2014 (G TALLY DC 24 V/TTL)
These switches are set according to the signal standard of
the G TALLY signal input to the INTERCOM/TALLY/
PGM connector on the CCU rear panel. For the relation
between the signal and switch setting, refer to the table below.
Factory setting : (S2012) POWER
(S2014) DC 24 V
Switch
Contact
S2011, S2012
Contact
S2013, S2014
DC 24 V or TTL
. SW1000 (MIC GAIN ... CH1)
. SW1001 (MIC GAIN ... CH2)
Use these screws to adjust the microphone amplifier gain
for the camera adaptor. The standard level (NORM) is 0
dB, and the gain setting can be adjusted to any of 16 levels
from _12 dB (MIX) to +12 dB.
Signal input method
Power (+ + + + + 24 V) TTL (+ + + + + 5 V)
Power
Power
DC24 V
TTL