Ventilation Requirements - Baumatic B602.1BL/W User Manual

Table of Contents

Advertisement

Additional built under ventilation requirements
o Remove the horizontal strengthening support at the upper front
o If your housing unit incorporates a domestic lower drawer, this
o A 5 mm ventilation gap must be allowed between the top of the
Additional tall housing ventilation requirements
o A 500 x 15 mm cut out must be made in the top of the housing
o If the unit is fitted flush with the kitchen ceiling, a 20 cm²
Downloaded from
www.Manualslib.com
housing unit.
must be made non-functioning with a ventilated false front.
appliance and the underside of the worktop.
unit, the plinth and any other additional shelves apart from the
support shelf.
ventilation cut out must be made in the top front of the housing.
manuals search engine
o For both times of
installation, ensure that the
oven has been securely fixed
into the housing unit. The
fixing of the oven into the
housing is made by using
four screws. These should be
screwed through the oven
cabinet and into the housing
unit.