Installation Checklist; Materials Required; Minimum Fireplace Dimensions - Regency L390E Owners & Installation Manual

Gas insert
Hide thumbs Also See for L390E:
Table of Contents

Advertisement

INSTALLATION
INSTALLATION
CHECKLIST
Before installing vent system ensure that the damper
plate is open and secure to prevent the damper plate
from falling down and crushing the liner.
The Regency Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer to
sections "Minimum Fireplace Dimensions and
Clearances to Combustibles)
2) Make the gas connection. (Refer to section "Gas
Connection")
3) Install the two 3" fl ue liners (intake and exhaust)
to the sliding connector plate. (Refer to section
"Flue Liner Installation.")
4) Slide the unit half way into the fi replace.
5) Pull the vent connector plate through the tapered
brackets and fasten to the front plate. Refer to
section "Flue Liner Installation.")
6) Slide the unit fully into the fi replace. Level if
necessary.
7) Install 4-AA batteries into receiver. This unit will
not operate without AA batteries in place.
8) Test gas pressure (Refer to section "Gas Pipe
Pressure Testing"). Check aeration system
(Refer to section "Gas Insert Aeration System").
9) Install standard and optional features. Refer to
the following sections:
a. Brick Panels
b. Enamel Panels
c. Log Set
d. Glass Crystals
e. Spa stones
f. Low Profi le Faceplate
g. Optional Screen
10) Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is fi ring correctly. This includes:
a) Clocking the appliance to ensure the correct
fi ring rate.
b) Adjusting the primary air, if required, to
ensure that the fl ame does not carbon. See
"Gas Insert Aeration System" section.
c) Ensuring that the appliance is venting
correctly.
10

MATERIALS REQUIRED

No electrical power supply is required for the gas
control to operate. A 120 Volt AC power cord is
hooked up to the fan(if installed). Plug the 3 wire
cord into a suitable receptacle. Do not cut the
ground terminal off under any circumstances.
When connected with 120 volts, the appliance must
be electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada)
or in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70-1987.
MINIMUM FIREPLACE
DIMENSIONS
The minimum fi replace clearances & dimensions
for the Regency gas insert are shown in the
following diagrams:
A
B
C
D
E
Max Lentil
Bar Depth
Height
Depth
A
B
Low
10"
20"
15.5"
Profi le
Faceplate
Width
Width
(rear)
(front)
C
D
E
22"
30"
L390E / HZI390E Direct Vent Gas Insert

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hzi390e

Table of Contents