Advertisement

Input BTU/Hr Maximum
Input BTU/Hr Minimum
KWH (Maximum)
KWH (Minimum)
Orifice
Air Shutter Opening
Gas Inlet Shutoff Valve (pipe)
NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
35657-4-1015

SPECIFICATIONS

DV25IN(3,7)3L
LP
NAT
25,000
25,000
17,000
17,000
7.3
7.3
5
5
#53 (0.0596)
#42 (0.0935)
Full Open
1/8"
1/2 NPT
1/2 NPT
GAS SUPPLY PRESSURES
GAS TYPE
MAXIMUM
NAT
14
LP
14
DV33IN(3,7)3L
LP
NAT
33,000
33,000
25,000
23,000
9.57
9.57
7.30
6.67
1.55mm
#36 (0.1065)
Full Open
1/4"
1/2 NPT
1/2 NPT
MINIMUM
MANIFOLD
4.5
3.5
11
10
DV35IN(3,7)3L
LP
NAT
35,000
35,000
27,000
25,000
10.15
10.15
7.83
7.30
1.65mm (0.65)
#35 (.110)
Full Open
1/4"
1/2 NPT
1/2 NPT