For Standing Pilot Ignition Wiring: Appliance Requirements
DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL
VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED.
Optional Wall Switch
Position the wall switch in the desired position on a wall. Run a
maximum of 25 feet (7.8m) or less length of 18 A.W.G. minimum
wire and connect it to the fireplace valve pigtails.
DO NOT CONNECT THE 110-120 VAC TO THE WALL SWITCH
OR THE CONTROL VALVE WILL BE DESTROYED.
Page 32
STANDING PILOT WIRING
WARNING
WARNING
STANDING PILOT WIRING DIAGRAM
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROL. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not
cut or remove the groundig prong from this plug.
Figure 22
WARNING
WARNING
35657-4-1015