Analog Return Path; Digital Return Path - Motorola Starline SG 2000 Installation And Operation Manual

Telecommunications optical node
Table of Contents

Advertisement

3 - 1 0
B e n c h S e t u p

Analog Return Path

Figure 3-1 illustrates the location of the return-path transmitter modules.
To set up analog return-path transmitters:
1
Confirm the transmitter configuration required. For a single transmitter, use the optical
transmitter A position. The redundant transmitter uses the optical transmitter B position.
Redundancy options are discussed in Section 5, "Operation."
2
For each return-path transmitter, measure the optical power level at the test point provided on the
top panel of the transmitter as illustrated in Figure 5-12. The scaled voltage present at this test
point is 1.0 V/mW.
3
Verify that the green LED (
confirm enable status. Refer to Section 5, "Operation," for
4
Review return-path system levels. The unit is configured to drive the laser to the recommended
level (+15 dBmV) when the total combined power at all ports is approximately +28 dBmV.

Digital Return Path

To set up digital return-path transmitters:
1
Confirm the transmitter configuration required. For a single transmitter, use the optical
transmitter A position. The redundant transmitter uses the optical transmitter B position.
Redundancy options are discussed in Section 5, "Operation."
2
Verify that the green LED (
to Section 5, "Operation," for
3
Review return-path system levels. The unit is configured to drive the laser to the recommended
level (+15 dBmV) when the total combined power at all ports is approximately +28 dBmV.
Two models of return path modules are available with analog and digital transmitters:
With the SG 2000 return path module/combined (SG2-RPM/C), the total combined power at
T
all four ports totals approximately +28 dBmV.
With the SG 2000 return path module/split (SG2-RPM/S), the total combined power at each
T
pair of ports is approximately +28 dBmV.
For more specific information regarding return path setup procedures, refer to the supplemental
document Return Path Level Selection, Setup, and Alignment Procedure.
S G 2 0 0 0 I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
), located on the top panel of the transmitter, is illuminated to
ON
), located on the top panel of the transmitter, is illuminated. Refer
ON
LED functions.
FAULT
LED functions.
FAULT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents