Download Print this page

Condensate Outlet - Aerial AP 50 Instruction Manual And Warranty

Hide thumbs Also See for AP 50:

Advertisement

Instruction manual swimming pool dryer AP 50 / AP 70

6.3 Condensate outlet

The air dryers of the AP-series are serially equipped with fittings for 12 mm hoses. The
connecting piece is placed at the left side of AP 50 and AP 70 (right at the bottom). Make sure
that the hose is fixed with a clamp and the condensate can flow off certainly.
Attention!
The end of the hose must be situated lower than the beginning of the hose (runoff socket)!
The hose must never be bent!
No objects must be placed onto the hose!
Check regularly whether the condensate can flow off certainly. Otherwise, a new hose
might be mounted.
6.4 Automatic defrosting
During air drying, ice may form at the evaporator. The volume of ice depends on the ambient
conditions prevailing in the room to be dried. The air dryer is equipped with an automatic hot-
gas defroster. It ensures that, depending on the extent of ice formation, the appliance will be
defrosted automatically according to the following principle:
A temperature sensor measures the condition existing in a critical area of the evaporator.
It transmits the signal for defrosting to the DryLogic-electronic. The DryLogic finds out if
defrosting is necessary, and it will start defrost-mode on its own.
During defrosting the compressor works and the fan does not work. When the ice is
defrosted, the dehumidifier will start again with dehumidifying
Operating conditions
AP-condensation dryer are suitable for the effort in swimming halls. AP-condensation dryer
work problem-free at the temperature range of +3 to +32°C and in the case of relative humidity
from 40% to 95% r.h..
The built-in ThemoLogic switches off the device while falling below or exceeding the
permissible room temperature and switches on again as soon as the room temperature lies in
the permissible field again..
Attention!
The appliance must not be used under the following conditions:
in rooms of potentially explosive atmosphere
in rooms of aggressive atmospheres, for example ammonia and wood acid
In rooms with water which shows a pH-value outside of 7,0 to 7,4. Remark: In the case of
lower pH-value, corrosion occurs at all metals and damages occurs at mortar containing
materials. In the case of higher pH-value, it comes to irritation of skin and eye mucous
membrane and extreme lime deposits.
in rooms featuring a high concentration of solvents
in rooms of an extremely high ratio of dust
In the case of doubtful operating conditions it is recommended to contact the Technical
Department of Messrs. AERIAL or a specialized dealer.
Using an AP-air dryer under inadequate operating conditions will entail that the
warranty becomes null and void.
From serie July 2003
page 5
AERIAL GmbH

Hide quick links:

Advertisement

loading

This manual is also suitable for: