AERIAL GmbH 1 General advice You have bought an air dryer made by AERIAL thus deciding for a proven quality product "Made in Germany". If nevertheless complications should occur, you will find some advice hereinafter how to eliminate such difficulties as quickly as possible.
Authorized users The service of the condensation dryers AD 530, AD 630 and AD 630F may only be carried out by persons, that were instructed from the operator . The user is responsible in the field of action third parties compared to.
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 5 Electrical connection Before connecting the air dryer, the following items must be checked: Does the mains voltage coincide with the voltage of the appliance? Adequate fusing of socket and supply system? Has the required residual-current-operated circuitbreaker (r.c.c.b) been installed in case of...
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 6.2 Hygrostat control The air dryers of the AD-series dispose of a hygrostat for setting the required humidity value. This hygrostat is located in the hygrostat box inside the bucket compartment. It makes that the air dryer cuts in as soon as the ambient humidity exceeds the preset value.
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 6.4 Automatic defrosting During air drying, ice may form at the evaporator. The volume of ice depends on the ambient conditions prevailing in the room to be dried. The air dryer is equipped with an automatic hot- gas defroster.
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 8 Technical data Range of application +3 to +32°C, 40 to 95%r.h. Supply voltage, frequency 230V, 50Hz Safety class 1 acc. to VDE 0106 T1 Degree of protection IP23 acc. to DIN 40050 air flow 660 m³/h...
Page 9
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH The automatic circuit breaker The safeguard of the The building safeguard must be of the building disturbs the building is too weak. checked and/or transposed. voltage supply to the device.
Page 10
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH The dryer does not achieve The hygrostat is adjusted A condensation dryer can achieve the humidity adjusted at the onto a value below 45% r.h.. - depending on environmental...
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 10 Repair and maintenance Attention! When performing any repair or maintenance, the general safety rules and provisions must be adhered to! In order to guarantee a troublefree function of the dryer the device should be cleaned regularly.
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 12 Denotation of the most important components AD 530 Pos. Denotation Pos. Denotation compressor condenser Main cable (approx. 4,5 mtr.) Filter dryer DryLogic with sensor evaporator...
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 14 Denotation of the most important components AD 630 Pos. Denotation Pos. Denotation compressor condenser Main cable (approx. 4,5 mtr.) Filter dryer DryLogic with sensor evaporator...
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH 16 Denotation of the most important components AD 630F Pos. Denotation Pos. Denotation compressor condenser Main cable (approx. 4,5 mtr.) Filter dryer DryLogic with sensor evaporator...
Need help?
Do you have a question about the AD 530 and is the answer not in the manual?
Questions and answers