STEP 2
Selecting the Function Number and Setting Value
(1) Press the SET TEMP. (
(Press the MODE button to switch between the left and right digits.)
(2) Press the FAN button to proceed to setting the value.
(Press the FAN button again to return to the function number selection.)
(3) Press the SET TEMP. (
(Press the MODE button to switch between the left and right digits.)
(4) Press the TIMER MODE button, and START/STOP button, in the order listed to confirm the settings.
(5) Press the RESET button to cancel the function setting mode.
(6) After completing the FUNCTION SETTING, be sure to turn of the power and turn it on again.
Function number
8-2. JP(Jumper) SETTING
[Outdoor Unit]
07LGC
Normal Preheat
Higher Preheat
09LGC
Normal Preheat
Higher Preheat
12LGC
Normal Preheat
Higher Preheat
14LGC
Normal Preheat
Higher Preheat
- it is possible to select the higher or standard level of preheating function.
- When it is set up at the higher level of preheat, the magnetic noise of the compressor becomes higher.
) (
) buttons to select the function number.
) (
) buttons to select the setting the value.
Setting value
10 c HEAT
JM2
JM103
JM500
JM103
CAUTION
After turning off the power, wait 10 seconds or more
before turning on it again.
The FUNCTION SETTING doesn't become effective
if it doesn't do so.
JP
JM102
JM101
JP
JM102
JM101
08-03