Heating Operation - Fujitsu ASYA07LGC Service Instruction

Hide thumbs Also See for ASYA07LGC:
Table of Contents

Advertisement

2. HEATING OPERATION

2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is lower by 3°C than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is higher 2.5°C than a set temperatire, the compressor will be
stopped.
* When the room temperature is between +2.5°C to -3°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table2.
However, the maximum frequency is limited in the range shown in Figure 2 based on the
fan speed mode and the outdoor temperature.
( Table 2 : Compressor Frequency Range )
AS*A07/ 09LGC
AS*A12LGC
AS*A14LGC
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
Outside air
temperature
C zone
17°C
B zone
12°C
A zone
5°C
AA zone
* The room temperature is controlled 2°C higher than the setting temperature for 60 minutes
after starting the operation.
After 60 minutes, it is controlled based on the normal setting temperature.
minimum
maximum
frequency
frequency
22Hz
99Hz
18Hz
130Hz
18Hz
101Hz
Outside air
temperature
19°C
14°C
7°C
Hi
07LGC
AA zone
99Hz
09LGC
A zone
99Hz
B zone
99Hz
C zone
99Hz
AA zone
130Hz
12LGC
A zone
130Hz
B zone
130Hz
130Hz
C zone
AA zone
101Hz
14LGC
A zone
101Hz
B zone
101Hz
101Hz
C zone
05-02
Me+
Me
Lo
99Hz
96Hz
79Hz
99Hz
96Hz
79Hz
99Hz
96Hz
79Hz
99Hz
96Hz
79Hz
130Hz
96Hz
80Hz
130Hz
96Hz
80Hz
130Hz
96Hz
80Hz
130Hz
96Hz
80Hz
101Hz
75Hz
58Hz
101Hz
75Hz
58Hz
101Hz
75Hz
58Hz
101Hz
75Hz
58Hz
Quiet
67Hz
67Hz
56Hz
46Hz
68Hz
68Hz
54Hz
45Hz
45Hz
45Hz
38Hz
30Hz