Error Codes - Cub Cadet RZT-S Zero Shop Manual

Hide thumbs Also See for RZT-S Zero:
Table of Contents

Advertisement

Error codes

Message
For Best Battery Life Avoid
Information
Heavy Load
Only
Battery Low: Charge Soon
Information
Only
Reduce Speed: Overload/
Information
Allow Hub Motors to cool
Only
Battery icon blinking
Information
Only
Blades off: Low battery /
Information
Return home and plug into
Only
the charger
Blades Off: In Reverse /
Safety
Restart blades
To Start: Unplug charger
Safety/
Start disable
Message
Mower's action
type
Display message only
Display message only
Display message only
Battery icon blinking
Disables Blades; Reduces
Speed
Disables Blades
Will not start or will return
to start prompt
Code
number
Trigger
(engineering
screen)**
Battery power in the
Heavy Load range for 10
continuous seconds.
Battery state of charge
has fallen below 16%
One or more controllers
report a temperature of
o
60
or higher
Battery voltage greater
than 50.8V on power up,
causing reset of battery
state of charge estimate.
Battery pack state of
charge is at 16% or less
Mower is moving in
reverse
0 volts at pin B2
Possible causes
Load too heavy, short cir-
cuit or a faulty controller
Battery voltage greater
than 50.8V on power up,
causing reset of battery
state of charge estimate.
battery pack discharged,
poor battery cable connec-
tions, Note: dull blades will
greatly decrease battery
run time.
Not in mow in reverse
mode
Charger door open, poor
connection, faulty charger
door switch or a fault in the
harness

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents