Recent Close Delay; Auto-Test Report; Power Failure Report Delay; Disarm Reporting Options - Magellan MG-6060 Reference And Installation Manual

All-in-one wireless security system v1.2
Hide thumbs Also See for MG-6060:
Table of Contents

Advertisement

Table 11: Telephone Line Monitoring Options
Options
Description
[1]
[2]
OFF
OFF
TLM disabled (default)
OFF
ON
Trouble only: Upon a line test failure, a TLM trouble
will appear in the console's Trouble Display.
ON
OFF
Alarm if System Armed: Upon a line test failure, a
TLM trouble will appear in the console's Trouble
Display and if the system is armed, the console will
generate an alarm.
ON
ON
Silent Alarm becomes Audible: Upon a line test
failure, a TLM trouble will appear in the console's
Trouble Display and causes a silent zone or silent
panic alarm to switch to audible.
Please note that when the dialer detects an incoming call, the
TLM test will stop for 1 minute.
TLM Fail Timer
Section [073]: 001 to 255 seconds; 000 = Disabled; Default = 32
seconds
If TLM does not detect the existence of a telephone line for the
duration of this period, the control panel will generate the
condition(s) defined by the TLM options (see Telephone Line
Monitoring (TLM) on page 32).

Recent Close Delay

Section [066]: 001 to 255 seconds; 000 = Disabled;
Default = Disabled
If after having armed the system, an alarm is generated within
the period defined by the Recent Close Delay, the Magellan
console will attempt to transmit the Recent Close report code
programmed in section [139] (page 28).

Auto-Test Report

Section [071]: 001 to 255 days; 000 = Disabled; Default =
Disabled
Section [084]: Time (HH:MM)
The Magellan console will transmit the Test Report report code
programmed into section [153] after the number of days
programmed into section [071] has elapsed at the time
programmed into section [084]. Use the 24-hour clock to
program the time (i.e. 6:30PM = 18:30). The first Test Report will
be transmitted within 24 hours after the feature is enabled at the
time programmed in [084].
Example: Section [071] = 005 and section [084] = 13:00. The first
Test Report will be sent at 1 PM that day and then the report will
be sent every 5 days at 1 PM.

Power Failure Report Delay

Section [070]: 001 to 255 minutes; 000 = Disabled;
Default = 15 minutes
The Magellan console will transmit the AC Failure report code
programmed in section [149] after the Power Failure Report
Delay period has elapsed.
Paradox Magellan Systems

Disarm Reporting Options

Section [093]: Option [5]
Option [5] OFF = Always report disarming
Option [5] ON = Report disarming only after alarm (default)
With option [5] OFF, the Magellan console will send the
Disarming report codes (see page 28) to the monitoring station
every time the system is disarmed. With option [5] ON, the
console will send the Disarming report codes to the monitoring
station when the system is disarmed following an alarm.

Zone Restore Report Options

Section [094]: Option [2]
Option [2] OFF = Report on Bell Cut-Off (default)
Option [2] ON = Report on zone closure
With option [2] OFF, the Magellan console will send the Zone
Alarm Restore report codes (see page 28) to the monitoring
station when the zone has returned to normal and the Bell Cut-
Off Timer (see page 25) has elapsed. With option [2] ON, the
console will send the Zone Alarm Restore report codes to the
monitoring station as soon as the zone returns to normal or when
the system is disarmed.

RF Interference Detection

Section [096]: Option [8]
Option [8] OFF = RF Interference Detection disabled (default)
Option [8] ON = RF Interference Detection enabled
With option [8] ON, a trouble will be generated when the
Magellan console's RF signal is jammed or encounters
interference for a minimum of 10 seconds.