Performance Data Sheet - Flowmatic FMRO5-M-MT Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. Do not use
with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certifi ed for cyst
reduction may be used on disinfected water that may contain fi lterable cysts.
2. This system is acceptable for treatment of infl uent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as
N and is certifi ed for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40
psi, Flowmatic recommends the use of a RO booster pump for proper operation.
3. Operating Temperature:
4. Operating Water Pressure:
5. pH
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
This system has been tested according to NSF/ANSI 58 for reduction of the substances below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specifi ed in NSF/ANSI 58. This system has been
tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or less. This system
reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual
at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not
suffi cient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data Sheet for further
information.
Avg. In.
Arsenic (Pentavalent)
334.62 ug/L
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent)
Chromium (Trivalent)
Copper Reduction
Cysts
222,077#/ml
Fluoride Reduction
Lead Reduction
Nitrite and Nitrate
Nitrate Reduction
Nitrite Reduction
Perchlorate
Radium 226/228
25pCi/L
Selenium
TDS
Turbidity
81 NTU
Recovery - 16.34%
Effi ciency rating means the percentage of the infl uent water to the system that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
There is an average of 4 gallons of reject water for every 1 gallon of product water produced. Testing performed under standard laboratory conditions,
actual performance may vary. Refer to owners manual for further maintenance requirements and warranty information.
Phone: (352) 465-2000

Performance Data Sheet

FMRO5-M-PT, FMRO5-M-MT
System conforms to NSF Standard 58 for specifi c claims.
Maximum: 100°F (40.5°C)
Maximum: 85 psi (5.95kg/cm2)
3 to 11
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Depending on incoming feed water conditions replacement time frame may vary.
Change Time
Description
6 months:
Sediment Pre-fi lter; Carbon Pre-fi lters
12 months
Final Carbon fi lter
2 to 5 years
R.O. Membrane
Avg. Eff.
% Reduction pH
(mg/L)
(mg/L)
5.039 ug/L
10.2
0.13
0.031
0.0001
0.30
0.006
0.30
0.003
3.0
0.04
10 #/ml
8.0
0.33
0.15
0.004
29.2
6.6
26.3
6.1
2.8
0.5
0.10
0.003
5pCi/L
0.10
<0.001
764
36
0.15 NTU
Recovery rating means the percentage of the infl uent water to the membrane portion of the system that
Flowmatic Systems Inc.
11611 SW 147 Court
Dunnellon, FL 34432 USA
Pressure
98.4%
50psi
98.7%
7.24
50psi
99.7%
7.49
50psi
98.0%
7.24
50psi
99.0%
7.24
50psi
98.7%
7.64
50psi
99.99%
50psi
95.9%
7.49
50psi
97.3%
7.49
50psi
77.3%
7.64
50psi
76.8%
7.64
50psi
82.1%
7.64
50psi
96.5%
7.39
50 psi
80.0%
7.24
50psi
99.0%
50psi
95.2%
7.84
50psi
99.8%
50psi
Daily Production Rate - 17.32 GPD
Page 18
Minimum: 40° (4.4°)
Minimum: 40 psi (2.8kg/cm2)
Max Eff.
Inf. challenge
mg/L
concentration
mg/L
19 ug/L
0.30±10%
0.27
10.0±10%
0.0009
0.03±10%
0.013
0.03±10%
0.008
0.03±10%
0.06
3.0±10%
58
minimum 50,000/mL
0.47
8.0±10%
0.008
0.15±10%
10.0
3.0±10%
10.0
3.0±10%
0.77
3.0±10%
0.005 mg/L
0.10±10%
5pCi/L
25pCiL±10%
<0.001
0.10±10%
50.0
750±40mg/L
0.28 NTU
11±1 NTU
Max Allowable
concentration
mg/L
0.010 mg/L
2.0
0005
0.1
0.1
1.3
N/A
1.5
0.0107
10.0
10.0
1.0
0.006
5pCiL
0.05
187
0.5 NTU
Effi ciency - 8.91%
Fax: (352) 465-4898

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Flowmatic FMRO5-M-MT

This manual is also suitable for:

Fmro5-m-pt

Table of Contents