Connect the Red Tube from Faucet to RO Module
Insert the red 1/4" tube from the faucet into the port on the
Step 27
module marked DRAIN. Make sure the tube is pushed in all
the way to the tube stop.

Final Filter Installation

Step 28
The Final Filter and 2 plastic connectors are in the parts
bag.
Step 29
Remove the blue/white caps from the fi nal fi lter.
Step 30
Thread the 3/8" plastic connector into the inlet side of the fi nal
fi lter and tighten. Thread the 1/4" connector to the outlet side of
fi nal fi lter (refer to directional arrow on fi lter).
Step 31
Push in 3/8" blue tube from the manifold into the 3/8"connector
on the fi nal fi lter.
Step 32
Insert the 1/4" blue tube from the faucet into the outlet of the
fi lter. Note: Flow arrow should be pointing toward the faucet.