Flowmatic FMR04-ZW Installation, Operation And Maintanance Manual

Zero waste reverse osmosis system

Advertisement

Quick Links

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Warning
Please read carefully before proceeding with installation. Your failure to follow a attached
instructions or operating parameters may lead to the product's failure and possible
damage to property.
*******************************************************************************************
Save manual for future reference.
Model FMRO4-ZW
ZER O WASTE R EVER SE OSMOSIS SYSTEM

Advertisement

Table of Contents
loading

Summary of Contents for Flowmatic FMR04-ZW

  • Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Warning Please read carefully before proceeding with installation. Your failure to follow a attached instructions or operating parameters may lead to the product's failure and possible damage to property. ******************************************************************************************* Save manual for future reference. Model FMRO4-ZW ZER O WASTE R EVER SE OSMOSIS SYSTEM...
  • Page 2: Table Of Contents

    Thank you for your purchase of a Flowmatic Reverse Osmosis system. With proper installation and maintenance, this system will provide you with high quality water for years to come. All of Flowmatic water enhancement products are rigorously tested by independent laboratories for safety and reliability. If you...
  • Page 3: Operational Parameters

    Operational Parameters Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Operating Temperatures: Maximum 100°F (37.8°C) Minimum 40°F ( 4.4°C) Operating Pressure: Maximum 100 psi (7.43 g/cm2) Minimum 40 psi (2.80 kg/cm2) pH Parameters: Maximum...
  • Page 4: Installation Of Faucet

    Installation of Faucet Caution: Porcelain sink surface material is extremely hard and may crack or chip. Use extreme caution when drilling. Watts accepts no responsibility for damage resulting from the installation of the faucet. Black Locating Washer (used where a 1/2" hole is available, reverse when mounting on stainless steel or when using drilled hole)
  • Page 5: Installation Of Hot And Cold Water Line Fittings

    Installation of hot and cold water supply line valves F o r 3 / 8 ” p l u mb i n g F o r 1 / 2 ” p l u mb i n g Hand tighten brass nuts then apply 1/4 turn with a wrench. To RO System 1/4"...
  • Page 6: Mounting The Ro Module

    Mounting the RO module Step 10 Determine the best location for the RO Module to be mounted and allow for future system maintenance. Use a Phillips screwdriver and secure the screws 5 3 / 4 ” a p a r t a n d 1 6 ” f r o m t h e b o t t o m o f t h e c a b i n e t . Note: There will be (2) Blue, (1) Green and (1) Black coming from the module.
  • Page 7: Installation Of Storage Tank

    Installation of Storage Tank Apply Teflon tape in a clockwise direction around the Step 15 male pipe threads on the tank. Thread the ball valve (supplied in the parts bag) onto the stainless steel connector on the tank. Note: Do not over tighten plastics connections. T h r e a d 1 / 4 ”...
  • Page 8: Start Up Instructions

    Start up Instructions Warning: To prevent the possibility of electrical shock, clean up any water on cabinet floor and dry all water from outside of RO unit. Turn on the incoming hot and cold water angle stop valves. Turn Step 1 on the water line needle valves by turning counter clockwise.
  • Page 9: Annual Maintenance

    Semi-annual maintenance continued Step 7 Inspect O-rings for wear and replace them if needed (order part no. WP113029 from Watts.) Lubricate O-rings with a water soluble lubricant such as KY Jelly®, (petroleum based lubricants such as Vaseline® must not be used.) Be sure to properly seat the O-ring in the housing before threading the housings onto the lid assembly.
  • Page 10: Membrane Maintenance

    Membrane Maintenance Membrane filters have a life expectancy of 2 to 5 years, depending on the incoming water conditions and the amount of use of the RO system. If at any time you notice a reduction in water production or a change in the taste of the RO water, it could be time to replace the membrane.
  • Page 11: Trouble Shooting

    Trouble shooting Problem Cause Solution Low/slow production Excessive air pressure in tank Relieve pressure at Schrader valve on tank (set to 7 psi with the tank empty) Wiring connection broken (plug 110 AC wall Pump not operating plug back in at wall and/or reconnect the 24 VAC wire harness connectors) Replace pump if needed Replace membrane...
  • Page 12: Adjust Faucet

    Adjust Faucet If the faucet has developed a drip it can be corrected by following the steps outlined below. Step 1 Remove faucet Spout first. Position both thumbs on the back edge of the lever and push forward. Step 2 Lever will slide forward and completely off of the faucet base.
  • Page 13: Service Record

    SERVICE RECORD SERIAL NO. DATE OF PURCHASE DATE OF INSTALL INSTALLED BY NAME: Date of (6 mos.) (6 mos.) (1 yr.) (2-5 yrs.) OTHER Maintenance 1st stage 2nd stage Final Filter TFM Memb. Sediment Carbon Block Carbon NOTES:...
  • Page 14: Warranty

    OTHER CONDITIONS: If Flowmatic chooses to replace the equipment, Flowmatic Systems may replace it with reconditioned equipment. Parts used in repairing or replacing the equipment will be warranted for 90 days from the date the equipment is returned to you or for the remainder of the original warranty period, whichever is longer.

Table of Contents