Summary of Contents for Zip HydroTap ABC10/30FXC

  • Page 1 Installation Instructions and Operating Procedures Zip HydroTap ® Filtered boiling and chilled water for kitchens and tea rooms 73078 Zip HydroTap ABC10/30FXC 73119 Zip HydroTap ABC30/30FXC 73081 Zip HydroTap ABA10FXC 73123 Zip HydroTap ABA30FXC 73118 Zip HydroTap ABB10FXC 73121 Zip HydroTap ABB30FXC...
  • Page 2 Page 2 of 20 Zip HydroTap Installation and Operating Instructions - 82872 - July 2003...
  • Page 3: Table Of Contents

    Contact Details ........20 Zip HydroTap Installation and Operating Instructions - 82872 - July 2003...
  • Page 4: Read These Warnings First

    Read These Warnings First Safety Do not allow young children, handicapped or infirm persons, to use the Zip HydroTap without supervision Refrigerant The Zip HydroTap Chilling unit contains 134A refrigerant under pressure. No part of the unit should be exposed to a naked flame. Maintenance of refrigeration unit must be carried out by an accredited service provider or qualified refrigeration mechanic.
  • Page 5: Models Covered By These Instructions

    Section Heading Models covered by these instructions These Installation Instructions cover the entire Zip HydroTap range. Use the chart on the left to identify the model you are using: Model: ABC = Filtered, boiling and chilled, timer ABA = Filtered, boiling and ambient...
  • Page 6: Special Tools Required

    Tighten the fixing screws firmly. Assembly Detail Tap Body Base Ring Sealing Ring Upper Metal Plate (Fits into recess in sealing ring) Sink Lower Metal Plate Fixing Screws Page 6 of 20 Zip HydroTap Installation and Operating Instructions - 82872 - July 2003...
  • Page 7: Step B - Installing The Undersink Unit (All Models)

    Before positioning heater connect the braided water inlet hose (supplied) to cold water inlet on unit. This is located on the left hand side. Position the Zip HydroTap undersink unit as closely as possible to directly beneath the Zip HydroTap tap head.
  • Page 8: Installation With Tap Font

    Remove protective coating from stainless steel, wipe clean and fit removable drip plate. Fit remaining tubes and cable as shown on page 7. Page 8 of 20 Zip HydroTap Installation and Operating Instructions - 82872 - July 2003...
  • Page 9 Detach this papertemplate and use it to position your Zip Hydrotap Tap-Font on your kitchen bench. Zip HydroTap Installation and Operating Instructions - 82872 - July 2003 Page a...
  • Page 10 MINIMUM 80 mm CLEARANCE 45 mm FROM REAR WALL. SMALL HOLE SCREW HOLE CIRCUMFERENCE OF TAP-FONT BASE SCREW HOLE...
  • Page 11 SCREW HOLE 57 mm SCREW HOLE LARGE HOLE...
  • Page 12 Detach this paper template and use it to position your Zip Hydrotap Tap-Font on your kitchen bench. Page d Zip HydroTap Installation and Operating Instructions - 82872 - July 2003...
  • Page 13: Installation Procedure Continued

    Vent Zip HydroTap Installation and Operating Instructions - 82872 - July 2003 Page 13 of 20...
  • Page 14: Step D - Connecting The Water Supply (All Models)

    Step D - Connecting the water supply (all models) Electrical Connection Cold Supply Water connection To prevent sediment from entering the Zip HydroTap at connection, flush water through the supply thoroughly before connection to the HydroTap. Stop Hot outlet cock Open the access door and check that the filter is in place and secure.
  • Page 15: Solving General Problems

    The filter is blocked Change the filter There is a problem with the Turn off the power and the water undersink unit and call your Zip service Provider Zip HydroTap Installation and Operating Instructions - 82872 - July 2003 Page 15 of 20...
  • Page 16: Operating The Tap

    To operate the tap when the child proof lock is activated, press and hold the child proof lock button in and then press the hot water button. Note: Whilst the Zip HydroTap is designed to dispense water within 2°C to 6°C of boiling point. The temperature can drop out of this range during heavy usage.
  • Page 17: Cleaning

    Undersink units must never be cleaned with water jets. Replacing the Filter The Zip HydroTap timer is set to remind you to replace your filter every 9 months. When a filter change is due, the Change Filter light will come on and remain on until reset.
  • Page 18: Setting The Energy Saver Timer

    Setting the Energy Saver Timer If you do NOT wish to programme the timer to turn the Zip HydroTap on and off daily, you may ignore the following instructions. The Zip HydroTap will operate continuously if you do not programme the timer at all.
  • Page 19: Warranty

    Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip's option to the replacement of the...
  • Page 20: Contact Details

    The standard glass is 200 ml (7 fl oz). The terms "Zip", "HydroTap" and "Hydroboil" are registered trade marks. www.zipheaters.co.uk Zip products described in this publication are manufactured under one or more of the following Telephone: 0870 608 8888 patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, Facsimile: 01362 692448 and US5099825.