Led Indicator; Outdoor Temperature Sensor; Wiring Connections - Lennox X4146 Installation Instructions Manual

Elite series
Hide thumbs Also See for X4146:
Table of Contents

Advertisement

1 − Make wiring connections per the
appropriate wiring diagram on
pages 6 and 7. Refer to the table
below for terminal designations.
Terminal
First−stage heating
W
(conventional)
S1
Remote outdoor sensor
S2
Remote outdoor sensor
R
24V power
O
Reversing valve
B
Reversing valve
G
Fan relay
First−stage compressor
Y
(Conventional or
heat pump)
C
24V common
L
Equipment monitor
2 − Refer to inner terminal labels when
using the thermostat with conven-
tional systems (gas, oil or electric
heat plus air conditioning). Refer to
outer terminal labels in heat pump
applications. See figure below.
3 − Loosen screws of terminals that will
be used. Insert appropriate wires in
the terminal block under the loos-
ened screws. Securely tighten
each screw.
Description
Page 5
WALLPLATE
WIRE HOLE
LABELED WIRES
INSERT WIRE IN HOLE
4 − Connect wires to the correspond-
ing screw terminals per the ap-
propriate diagram.
5 − Push excess wire back into the
wall.
6 − Plug hole with nonflammable in-
sulation to prevent drafts from af-
fecting thermostat.

LED Indicator

An LED indicator is located in the up-
per right corner of the thermostat. It is
only visible when lit.
When an equipment monitor is con-
nected to the thermostat L terminal,
the LED lights when the monitor sends
a check or failure message to the ther-
mostat.
The LED requires the use of 24Vac
common power. The indicator will not
light when the thermostat is powered
by the batteries alone, or when 24Vac
power is interrupted.

Outdoor Temperature Sensor

Install the optional outdoor tempera-
ture sensor (X4148) as outlined in the
instructions provided with the sensor.
TERMINAL
BLOCK
LETTER
DESIGNATIONS
R
O
B
G
Y
C
SCREW
TERMINALS