Selection Description
(Factory setting in bold print)
0 − Daylight savings disabled.
1 − Daylight savings enabled.
Factory setting.
0 − No remote outdoor temperature
sensor. Factory setting.
1 − Outdoor temperature sensor used for
display only.
2 − Outdoor temperature sensor used to
control heat pump lock−out settings.
0 − Filter change reminder off.
Factory setting.
1 − 10 run time days.
2 − 30 run time days.
3 − 60 run time days.
4 − 90 run time days.
5 − 120 run time days.
6 − 365 run time days.
0 − Humidifier pad replacement remind-
er off. Factory setting.
1 − 90 run time days.
2 − 180 run time days.
3 − 365 run time days.
0 − UV lamp replacement reminder off.
Factory setting.
1 − 365 run time days.
Page 12
Notes
Set to 0 in
areas that
do not
do not
follow
daylight
savings.
Defaults
and
options
depend
on system
on system
type
selection.
When set-
ting 0210
is set to 0,
is set to 0,
setting
defaults to
2 and
item is not
shown.
Run time
based on
based on
call for
fan.